2004Meitan xuebaoRequires access

Mensuration of trace As in coal by flow injection-hydride generation-atomic absorption spectrometry

PI Zhong-yuan

Open publisher page 0 citations

Abstract

The method of mensurating trace As in coal by flow injection-hydride generation-atomic absorption spectrometry (FI-HG-AAS) was studied.The optimal conditions for hydride generation were investigated.The interference of the coexisting elements were prevented due to mensuration in coal.The method was applied to mensurate As in national standard reference materials.The results were in good agreement with the certified values.The detection limit was 0.14 ng/mL and the recovery of method was founded to be 94%~105% while the relative standard deviation(RSD) was 2.75%~7.45%(n=10).

About this research paper

What this paper is about

The method of mensurating trace As in coal by flow injection-hydride generation-atomic absorption spectrometry (FI-HG-AAS) was studied.The optimal conditions for hydride generation were investigated.The interference of the coexisting elements were prevented due to mensuration in coal.The method was applied to mensurate As in national standard reference materials.The results were in good agreement with the certified values.The detection limit was 0.14 ng/mL and the recovery of method was founded to be 94%~105% while the relative standard deviation(RSD) was 2.75%~7.45%(n=10).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The method of mensurating trace As in coal by flow injection-hydride generation-atomic absorption spectrometry (FI-HG-AAS) was studied.The optimal conditions for hydride generation were investigated.The interference of the coexisting elements were prevented due to mensuration in coal.The method was applied to mensurate As in national standard reference materials.The results were in good agreement with the certified values.The detection limit was 0.14 ng/mL and the recovery of method was founded to be 94%~105% while the relative standard deviation(RSD) was 2.75%~7.45%(n=10).

Key concepts: Hydride, Detection limit, Atomic absorption spectroscopy, Relative standard deviation, Chemistry, Certified reference materials, Analytical Chemistry (journal), Coal

Related papers

Back to paper searchBrowse research topicsOriginal source
Mensuration of trace As in coal by flow injection-hydride generation-atomic absorption spectrometry — Research Paper | ScholarLens