2014•Pharmaceutical Journal of Chinese People's Liberation ArmyRequires access

Determination of Chlorogenic Acid in Anti-inflammatory Granules by RP-HPLC

Wang Jun-ji

Open publisher page 0 citations

Abstract

Objective To establish an HPLC method for the determination of chlorogenic acid in anti-inflammatory granules. Methods C18column( 150 mm × 4. 6 mm,5 μm) was used. The mobile phase consisted of 0. 1% phosphoric acid solution-acetonitrile( 9∶ 91) at a flow rate of 1. 0 ml·min- 1. The temperature of the column was 30 ℃ and the detection wavelength was 327 nm. Results There was a good linear relationship within the range of 8. 128- 60. 96 μg·ml- 1( r =0. 9998). The average recovery rate was 99. 34%,with an RSD of 0. 41%( n = 9). Conclusion This method is quick,accurate,sensitive,repeatable and can be used for quality control of anti-inflammatory granules.

About this research paper

What this paper is about

Objective To establish an HPLC method for the determination of chlorogenic acid in anti-inflammatory granules. Methods C18column( 150 mm × 4. 6 mm,5 μm) was used. The mobile phase consisted of 0. 1% phosphoric acid solution-acetonitrile( 9∶ 91) at a flow rate of 1. 0 ml·min- 1. The temperature of the column was 30 ℃ and the detection wavelength was 327 nm. Results There was a good linear relationship within the range of 8. 128- 60. 96 μg·ml- 1( r =0. 9998). The average recovery rate was 99. 34%,with an RSD of 0. 41%( n = 9). Conclusion This method is quick,accurate,sensitive,repeatable and can be used for quality control of anti-inflammatory granules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish an HPLC method for the determination of chlorogenic acid in anti-inflammatory granules. Methods C18column( 150 mm × 4. 6 mm,5 μm) was used. The mobile phase consisted of 0. 1% phosphoric acid solution-acetonitrile( 9∶ 91) at a flow rate of 1. 0 ml·min- 1. The temperature of the column was 30 ℃ and the detection wavelength was 327 nm. Results There was a good linear relationship within the range of 8. 128- 60. 96 μg·ml- 1( r =0. 9998). The average recovery rate was 99. 34%,with an RSD of 0. 41%( n = 9). Conclusion This method is quick,accurate,sensitive,repeatable and can be used for quality control of anti-inflammatory granules.

Key concepts: Chlorogenic acid, Phosphoric acid, Chromatography, High-performance liquid chromatography, Chemistry, Linear range, Linear relationship, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorogenic Acid in Anti-inflammatory Granules by RP-HPLC — Research Paper | ScholarLens