2007•Zhongguo sheng-hua yaowu zazhiRequires access

Determination of curcumol and germacrone in Zedoary Turmeric Oil Injections by RP-HPLC

Yu Wang

Open publisher page 0 citations

Abstract

Purpose To develop a HPLC method for the determination of curcumol and gemacrone in Zedoary Turmeric Oil Injections.Methods The HPLC system consisted of a Agilent TC ODS column(4.6 mm×15 cm,5 μm)and DAD detecter at 210 nm,the flow rate was 1.0 mL/min,and the mobile phase was composed ofmobile phase A:acetonitrile-methanol-water-phosphoric acid(550∶225∶225∶1) and mobile phase B:methanol as gradient mode.Results It shows a good linear range of 0.940 6~94.06 μg/mL(curcumol)and 1.333~133.2 μg/mL(germacrone).The recoveries of curcumol and gemacrone were 100.70% and 100.37% repectively.Conclusion The method is appropriate for the determination of curcumol and gemacrone in Zedoary Turmeric Oil Injections.

About this research paper

What this paper is about

Purpose To develop a HPLC method for the determination of curcumol and gemacrone in Zedoary Turmeric Oil Injections.Methods The HPLC system consisted of a Agilent TC ODS column(4.6 mm×15 cm,5 μm)and DAD detecter at 210 nm,the flow rate was 1.0 mL/min,and the mobile phase was composed ofmobile phase A:acetonitrile-methanol-water-phosphoric acid(550∶225∶225∶1) and mobile phase B:methanol as gradient mode.Results It shows a good linear range of 0.940 6~94.06 μg/mL(curcumol)and 1.333~133.2 μg/mL(germacrone).The recoveries of curcumol and gemacrone were 100.70% and 100.37% repectively.Conclusion The method is appropriate for the determination of curcumol and gemacrone in Zedoary Turmeric Oil Injections.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose To develop a HPLC method for the determination of curcumol and gemacrone in Zedoary Turmeric Oil Injections.Methods The HPLC system consisted of a Agilent TC ODS column(4.6 mm×15 cm,5 μm)and DAD detecter at 210 nm,the flow rate was 1.0 mL/min,and the mobile phase was composed ofmobile phase A:acetonitrile-methanol-water-phosphoric acid(550∶225∶225∶1) and mobile phase B:methanol as gradient mode.Results It shows a good linear range of 0.940 6~94.06 μg/mL(curcumol)and 1.333~133.2 μg/mL(germacrone).The recoveries of curcumol and gemacrone were 100.70% and 100.37% repectively.Conclusion The method is appropriate for the determination of curcumol and gemacrone in Zedoary Turmeric Oil Injections.

Key concepts: Chemistry, Chromatography, High-performance liquid chromatography, Methanol, Phosphoric acid, Acetonitrile, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of curcumol and germacrone in Zedoary Turmeric Oil Injections by RP-HPLC — Research Paper | ScholarLens