2010China Journal of Chinese Materia MedicaRequires access

HPLC determination of six components in zedoary turmeric oil and its related injections

Huan He

Open publisher page 1 citations

Abstract

OBJECTIVE: To establish an HPLC method to simultaneously determine six ingredients in zedoary turmeric oil and its related injections. METHOD: HPLC analysis was performed on Waters Symmetry C18 (4.6 mm x 250 mm, 5 microm). The mobile phase was composed of methanol and water solution in gradient elution mode with at a flow rate of 1.0 mL x min(-1). The column temperature was 30 degrees C and the UV detection wavelength was 215 nm. RESULT: The six ingredients were separated well. The linear ranges of curdione, curcumol, germacrone, curzerene, furanodiene and beta-elemene were 1.74-347.00, 2.38-475.00, 2.49-497.00, 2.07-826.00, 5.05-1009.00, 4.78-955.00 mg x L(-1) (r > or = 0.9996), respectively. The average recoveries were above 95% (RSD <3.0%, n=9). CONCLUSION: The method is accurate, reliable and reproducible, it can be used for the quality control of zedoary turmeric oil and its related injections.

About this research paper

What this paper is about

OBJECTIVE: To establish an HPLC method to simultaneously determine six ingredients in zedoary turmeric oil and its related injections. METHOD: HPLC analysis was performed on Waters Symmetry C18 (4.6 mm x 250 mm, 5 microm). The mobile phase was composed of methanol and water solution in gradient elution mode with at a flow rate of 1.0 mL x min(-1). The column temperature was 30 degrees C and the UV detection wavelength was 215 nm. RESULT: The six ingredients were separated well. The linear ranges of curdione, curcumol, germacrone, curzerene, furanodiene and beta-elemene were 1.74-347.00, 2.38-475.00, 2.49-497.00, 2.07-826.00, 5.05-1009.00, 4.78-955.00 mg x L(-1) (r > or = 0.9996), respectively. The average recoveries were above 95% (RSD <3.0%, n=9). CONCLUSION: The method is accurate, reliable and reproducible, it can be used for the quality control of zedoary turmeric oil and its related injections.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish an HPLC method to simultaneously determine six ingredients in zedoary turmeric oil and its related injections. METHOD: HPLC analysis was performed on Waters Symmetry C18 (4.6 mm x 250 mm, 5 microm). The mobile phase was composed of methanol and water solution in gradient elution mode with at a flow rate of 1.0 mL x min(-1). The column temperature was 30 degrees C and the UV detection wavelength was 215 nm. RESULT: The six ingredients were separated well. The linear ranges of curdione, curcumol, germacrone, curzerene, furanodiene and beta-elemene were 1.74-347.00, 2.38-475.00, 2.49-497.00, 2.07-826.00, 5.05-1009.00, 4.78-955.00 mg x L(-1) (r > or = 0.9996), respectively. The average recoveries were above 95% (RSD <3.0%, n=9). CONCLUSION: The method is accurate, reliable and reproducible, it can be used for the quality control of zedoary turmeric oil and its related injections.

Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Gradient elution, Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC determination of six components in zedoary turmeric oil and its related injections — Research Paper | ScholarLens