2011•Drug Evaluation ResearchRequires access

Determination of residual organic solvents in Moxifloxacin by capillary gas chromatography

WU Fang-ning

Open publisher page 0 citations

Abstract

Objective To develop a gas chromatography method for the determination of residual organic solvents in Moxifloxacin.Methods The samples were injected into INNOWAX capillary column and analyzed with FID detector using acetonitrile as the internal standard.Results The linear ranges of ethyl ether,methanol,and DMF were 50—800 μg/mL (r=0.999 8),30—480 μg/mL (r=0.999 9),and 8.8—140.8 μg/mL (r=0.999 6),respectively.The recoveries were 99.71%,100.30%,and 99.54%;RSD were 1.87%,1.32%,and 1.67%,respectively (n=9).Conclusion The method is simple,accurate,and sensitive with good reproducibility.It can be used for the determination of the residual organic solvents in Moxifloxacin.

About this research paper

What this paper is about

Objective To develop a gas chromatography method for the determination of residual organic solvents in Moxifloxacin.Methods The samples were injected into INNOWAX capillary column and analyzed with FID detector using acetonitrile as the internal standard.Results The linear ranges of ethyl ether,methanol,and DMF were 50—800 μg/mL (r=0.999 8),30—480 μg/mL (r=0.999 9),and 8.8—140.8 μg/mL (r=0.999 6),respectively.The recoveries were 99.71%,100.30%,and 99.54%;RSD were 1.87%,1.32%,and 1.67%,respectively (n=9).Conclusion The method is simple,accurate,and sensitive with good reproducibility.It can be used for the determination of the residual organic solvents in Moxifloxacin.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a gas chromatography method for the determination of residual organic solvents in Moxifloxacin.Methods The samples were injected into INNOWAX capillary column and analyzed with FID detector using acetonitrile as the internal standard.Results The linear ranges of ethyl ether,methanol,and DMF were 50—800 μg/mL (r=0.999 8),30—480 μg/mL (r=0.999 9),and 8.8—140.8 μg/mL (r=0.999 6),respectively.The recoveries were 99.71%,100.30%,and 99.54%;RSD were 1.87%,1.32%,and 1.67%,respectively (n=9).Conclusion The method is simple,accurate,and sensitive with good reproducibility.It can be used for the determination of the residual organic solvents in Moxifloxacin.

Key concepts: Chromatography, Chemistry, Moxifloxacin, Gas chromatography, Reproducibility, Capillary gas chromatography, Methanol, Ethyl acetate

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of residual organic solvents in Moxifloxacin by capillary gas chromatography — Research Paper | ScholarLens