Determination of Ursolic Acid in Compound Flavone Capsule by HPLC

LU Wen-sheng

Open publisher page 0 citations

Abstract

Objective To establish the method for determining the content of ursolic acid in Compound Flavone Capsules.Methods The C18 column with methanol-waterphosphorous acid(90∶10∶0.03) as the mobile phase was used.The flow rate was 0.5 ml/min and the detective wavelength was 220 nm.Results The linear range of calibration curve was 0.982~9.82 μg/ml(r = 0.999 8).The average recovery was 98.32% and the RSD was 0.56%(n= 6).Conclusion The method is simple and accurate with a good reproducibility.It can be used for the quality control of Compound Flavone Capsules.

About this research paper

What this paper is about

Objective To establish the method for determining the content of ursolic acid in Compound Flavone Capsules.Methods The C18 column with methanol-waterphosphorous acid(90∶10∶0.03) as the mobile phase was used.The flow rate was 0.5 ml/min and the detective wavelength was 220 nm.Results The linear range of calibration curve was 0.982~9.82 μg/ml(r = 0.999 8).The average recovery was 98.32% and the RSD was 0.56%(n= 6).Conclusion The method is simple and accurate with a good reproducibility.It can be used for the quality control of Compound Flavone Capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish the method for determining the content of ursolic acid in Compound Flavone Capsules.Methods The C18 column with methanol-waterphosphorous acid(90∶10∶0.03) as the mobile phase was used.The flow rate was 0.5 ml/min and the detective wavelength was 220 nm.Results The linear range of calibration curve was 0.982~9.82 μg/ml(r = 0.999 8).The average recovery was 98.32% and the RSD was 0.56%(n= 6).Conclusion The method is simple and accurate with a good reproducibility.It can be used for the quality control of Compound Flavone Capsules.