2007Journal of Practical Medical TechniquesRequires access

The Evaluation of OLYMPUS AU2700 Automatic Biochemical Analyzer

Donghong Lin

Open publisher page 0 citations

Abstract

Objective To use and evaluate OLYMPUS AU2700 automatic biochemical analyzer.Methods Using OLYMPUS AU2700 automatic biochemical analyzer, we make the test of repeatability, linearity and cross contamination rate etc.Furthermore, we compare the operating situation of one OLYMPUS AU2700 with another.Results All the CV of repeatability test are less than 3%.The results of linearity test show linear correlation(F0.9995).And the average of linearity rate is 0.14%.The stability of OLYMPUS AU2700 and homogeneity of cuvette are ex-cellent.Using two OLYMPUS AU2700 to test the same sample,the results of both are very similar.Conclusion OLYMPUS AU2700 automatic biochemical analyzer has the virtue of good repeatability,linearity and low cross contamination rate.It can suit for clinical demand of hospital.It is re-commendable to use it.

About this research paper

What this paper is about

Objective To use and evaluate OLYMPUS AU2700 automatic biochemical analyzer.Methods Using OLYMPUS AU2700 automatic biochemical analyzer, we make the test of repeatability, linearity and cross contamination rate etc.Furthermore, we compare the operating situation of one OLYMPUS AU2700 with another.Results All the CV of repeatability test are less than 3%.The results of linearity test show linear correlation(F0.9995).And the average of linearity rate is 0.14%.The stability of OLYMPUS AU2700 and homogeneity of cuvette are ex-cellent.Using two OLYMPUS AU2700 to test the same sample,the results of both are very similar.Conclusion OLYMPUS AU2700 automatic biochemical analyzer has the virtue of good repeatability,linearity and low cross contamination rate.It can suit for clinical demand of hospital.It is re-commendable to use it.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To use and evaluate OLYMPUS AU2700 automatic biochemical analyzer.Methods Using OLYMPUS AU2700 automatic biochemical analyzer, we make the test of repeatability, linearity and cross contamination rate etc.Furthermore, we compare the operating situation of one OLYMPUS AU2700 with another.Results All the CV of repeatability test are less than 3%.The results of linearity test show linear correlation(F0.9995).And the average of linearity rate is 0.14%.The stability of OLYMPUS AU2700 and homogeneity of cuvette are ex-cellent.Using two OLYMPUS AU2700 to test the same sample,the results of both are very similar.Conclusion OLYMPUS AU2700 automatic biochemical analyzer has the virtue of good repeatability,linearity and low cross contamination rate.It can suit for clinical demand of hospital.It is re-commendable to use it.

Key concepts: Repeatability, Spectrum analyzer, Linearity, Medicine, Homogeneity (statistics), Statistics, Mathematics, Electrical engineering