2004Pharmaceutical Journal of Chinese People's Liberation ArmyRequires access

Determination of Astragaloside IV in Fufang Hanfangji Granule by RP-HPLC

Peng Xue

Open publisher page 0 citations

Abstract

Aim To develop a method using RP-HPLC for determination the content of astragaloside Ⅳ in Fufang Hanfangji Granule.Methods The Alltech C 18 column(250mm×4.6mm,5μm) was used.The mobile phase was composed of acetonitrile-water (33∶67).The flow rate was 1ml/min.The column temperature was 30℃.An evaporative light scattering detector(ELSD) Model 2000 was used as detector.Results The linear range of astragaloside Ⅳ was 0.976~4.88μg(r=0.999 7,RSD=2.1%).The average recovery rate of astragaloside Ⅳ was 98.10%,and RSD=1.6%(n=5).Conclusion The method is simple and accurate and can be used reliably for the quality control of astragaloside Ⅳ in the compound Hanfangji Granule.

About this research paper

What this paper is about

Aim To develop a method using RP-HPLC for determination the content of astragaloside Ⅳ in Fufang Hanfangji Granule.Methods The Alltech C 18 column(250mm×4.6mm,5μm) was used.The mobile phase was composed of acetonitrile-water (33∶67).The flow rate was 1ml/min.The column temperature was 30℃.An evaporative light scattering detector(ELSD) Model 2000 was used as detector.Results The linear range of astragaloside Ⅳ was 0.976~4.88μg(r=0.999 7,RSD=2.1%).The average recovery rate of astragaloside Ⅳ was 98.10%,and RSD=1.6%(n=5).Conclusion The method is simple and accurate and can be used reliably for the quality control of astragaloside Ⅳ in the compound Hanfangji Granule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim To develop a method using RP-HPLC for determination the content of astragaloside Ⅳ in Fufang Hanfangji Granule.Methods The Alltech C 18 column(250mm×4.6mm,5μm) was used.The mobile phase was composed of acetonitrile-water (33∶67).The flow rate was 1ml/min.The column temperature was 30℃.An evaporative light scattering detector(ELSD) Model 2000 was used as detector.Results The linear range of astragaloside Ⅳ was 0.976~4.88μg(r=0.999 7,RSD=2.1%).The average recovery rate of astragaloside Ⅳ was 98.10%,and RSD=1.6%(n=5).Conclusion The method is simple and accurate and can be used reliably for the quality control of astragaloside Ⅳ in the compound Hanfangji Granule.

Key concepts: Astragaloside, Chromatography detector, Chromatography, Granule (geology), Chemistry, Linear range, High-performance liquid chromatography, Content determination

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Astragaloside IV in Fufang Hanfangji Granule by RP-HPLC — Research Paper | ScholarLens