2007Journal of Taishan Medical CollegeRequires access

Determination of paeonol in paeonol Ointment by HPLC

Haiwei Ji

Open publisher page 0 citations

Abstract

Objective: To establish an HPLC method for determination of Paeonol content in Paeonol Ointment.Methods: The content was determined by HPLC.The analysis was carried out on C18 column;the mobile phase consisted of methanol-water(60∶40);The flow rate was 1.0 ml/min,and the ultraviolet detection wavelength was at 274 nm.Results: The linear regression for Paeonol ranged from 0.112 to 1.12 μg(r=0.9997).The average recovery rate was 97.05% with RSD 1.35%.Conclusion: This method was sensitive,accurate,reproducible and exclusive.It can be used for quality control of Paeonol in Paeonol Ointment.

About this research paper

What this paper is about

Objective: To establish an HPLC method for determination of Paeonol content in Paeonol Ointment.Methods: The content was determined by HPLC.The analysis was carried out on C18 column;the mobile phase consisted of methanol-water(60∶40);The flow rate was 1.0 ml/min,and the ultraviolet detection wavelength was at 274 nm.Results: The linear regression for Paeonol ranged from 0.112 to 1.12 μg(r=0.9997).The average recovery rate was 97.05% with RSD 1.35%.Conclusion: This method was sensitive,accurate,reproducible and exclusive.It can be used for quality control of Paeonol in Paeonol Ointment.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish an HPLC method for determination of Paeonol content in Paeonol Ointment.Methods: The content was determined by HPLC.The analysis was carried out on C18 column;the mobile phase consisted of methanol-water(60∶40);The flow rate was 1.0 ml/min,and the ultraviolet detection wavelength was at 274 nm.Results: The linear regression for Paeonol ranged from 0.112 to 1.12 μg(r=0.9997).The average recovery rate was 97.05% with RSD 1.35%.Conclusion: This method was sensitive,accurate,reproducible and exclusive.It can be used for quality control of Paeonol in Paeonol Ointment.

Key concepts: Paeonol, Chromatography, High-performance liquid chromatography, Chemistry, Content determination, Medicine, Alternative medicine, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of paeonol in paeonol Ointment by HPLC — Research Paper | ScholarLens