2009Zhongguo yixue yingxiangxue zazhiRequires access

The Exploration of Radiation Dosage Control in the Chest Multi-slice CT Scan

Wang Hai-jun

Open publisher page 0 citations

Abstract

Purpose: To investigate the feasibility of reducing the radiation dose by adjusting the scan parameter in chest multi-slice CT examination.Materials and Methods: Randomly grouped 120 patients into control group and experimental group.The control group was consist of 63 cases,the scan parameter was 120 kV and 300 mA;the experimental group was consist of 57 cases,the scan parameter was 120 kV and 30~50 mA.Results: The image equality of the tow groups was of no significant difference,both reached the diagnostic standard.The mean CT dose indexes of control group and experimental group were 9.8mGy and 1.1mGy respectively.The dose of experimental group was lower than that of control group(P0.05).Conclusion: Low-dose chest CT scan provides diagnostically acceptable images with relevant diagnostic information,and the patients get the best radiation protection as well.

About this research paper

What this paper is about

Purpose: To investigate the feasibility of reducing the radiation dose by adjusting the scan parameter in chest multi-slice CT examination.Materials and Methods: Randomly grouped 120 patients into control group and experimental group.The control group was consist of 63 cases,the scan parameter was 120 kV and 300 mA;the experimental group was consist of 57 cases,the scan parameter was 120 kV and 30~50 mA.Results: The image equality of the tow groups was of no significant difference,both reached the diagnostic standard.The mean CT dose indexes of control group and experimental group were 9.8mGy and 1.1mGy respectively.The dose of experimental group was lower than that of control group(P0.05).Conclusion: Low-dose chest CT scan provides diagnostically acceptable images with relevant diagnostic information,and the patients get the best radiation protection as well.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: To investigate the feasibility of reducing the radiation dose by adjusting the scan parameter in chest multi-slice CT examination.Materials and Methods: Randomly grouped 120 patients into control group and experimental group.The control group was consist of 63 cases,the scan parameter was 120 kV and 300 mA;the experimental group was consist of 57 cases,the scan parameter was 120 kV and 30~50 mA.Results: The image equality of the tow groups was of no significant difference,both reached the diagnostic standard.The mean CT dose indexes of control group and experimental group were 9.8mGy and 1.1mGy respectively.The dose of experimental group was lower than that of control group(P0.05).Conclusion: Low-dose chest CT scan provides diagnostically acceptable images with relevant diagnostic information,and the patients get the best radiation protection as well.

Key concepts: Medicine, Nuclear medicine, Radiation dose, Computed tomography, Radiology, Radiation exposure, Effective dose (radiation)