2012Zhongguo yixue yingxiang jishuRequires access

Application of sinogram-affirmed iterative reconstruction technique in reducing radiation dose of chest CT examination

Jianbo Gao

Open publisher page 1 citations

Abstract

Objective To discuss the value of sinogram-affirmed iterative reconstruction(SAFIRE) technique in reducing radiation dose in chest CT examination.Methods Sixty-four patients underwent chest scan in Somatom Definition Flash CT with flash spiral model.Thirty-two patients underwent chest scan with 100kV and SAFIRE(value=3) reconstruction(low-dose group),while other 32patients underwent chest scan with 120kV and filter back projection(FBP) reconstruction(control group).CT values and standard deviation(SD) of descending aorta and muscle at the level of epibronchial were measured.CT dose index(CTDI) and dose length product(DLP) were compared.Two radiologists assessed the image quality with 5-point scale.The degree of interobserver concordance was evaluated using Kappatest.Results All images of both groups could satisfy diagnosis requirement,and the interobserver agreement for diagnosis acceptability was good(Kappavalue was 0.795).CTDI was(3.23±0.53) mGy in low-dose group,while(5.27±1.07) mGy in control group.DLP was(114.96±18.90) mGy.cm in low-dose group,while(184.40±36.85) mGy.cm in control group.The radiation dose was(1.60±0.26) mSv in low-dose group,while(2.58±0.51) mSv in control group(all P0.001).CT value of descending aorta was(39.90±8.31) HU in low-dose group and(43.12±7.43) HU in control group,SD was 13.61±2.00in low-dose group and 13.00±3.39in control group(all P0.05).CT value of muscle at the level of epibronchial was(45.50±11.85) HU in low-dose group and(48.23±10.99) HU in control group,SD was 10.34±1.55in low-dose group and 8.53±1.99in control group(all P0.05).Conclsion SAFIRE can reduce radiation dose in adult chest CT scan on the condition that the image quality was not affected.

About this research paper

What this paper is about

Objective To discuss the value of sinogram-affirmed iterative reconstruction(SAFIRE) technique in reducing radiation dose in chest CT examination.Methods Sixty-four patients underwent chest scan in Somatom Definition Flash CT with flash spiral model.Thirty-two patients underwent chest scan with 100kV and SAFIRE(value=3) reconstruction(low-dose group),while other 32patients underwent chest scan with 120kV and filter back projection(FBP) reconstruction(control group).CT values and standard deviation(SD) of descending aorta and muscle at the level of epibronchial were measured.CT dose index(CTDI) and dose length product(DLP) were compared.Two radiologists assessed the image quality with 5-point scale.The degree of interobserver concordance was evaluated using Kappatest.Results All images of both groups could satisfy diagnosis requirement,and the interobserver agreement for diagnosis acceptability was good(Kappavalue was 0.795).CTDI was(3.23±0.53) mGy in low-dose group,while(5.27±1.07) mGy in control group.DLP was(114.96±18.90) mGy.cm in low-dose group,while(184.40±36.85) mGy.cm in control group.The radiation dose was(1.60±0.26) mSv in low-dose group,while(2.58±0.51) mSv in control group(all P0.001).CT value of descending aorta was(39.90±8.31) HU in low-dose group and(43.12±7.43) HU in control group,SD was 13.61±2.00in low-dose group and 13.00±3.39in control group(all P0.05).CT value of muscle at the level of epibronchial was(45.50±11.85) HU in low-dose group and(48.23±10.99) HU in control group,SD was 10.34±1.55in low-dose group and 8.53±1.99in control group(all P0.05).Conclsion SAFIRE can reduce radiation dose in adult chest CT scan on the condition that the image quality was not affected.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To discuss the value of sinogram-affirmed iterative reconstruction(SAFIRE) technique in reducing radiation dose in chest CT examination.Methods Sixty-four patients underwent chest scan in Somatom Definition Flash CT with flash spiral model.Thirty-two patients underwent chest scan with 100kV and SAFIRE(value=3) reconstruction(low-dose group),while other 32patients underwent chest scan with 120kV and filter back projection(FBP) reconstruction(control group).CT values and standard deviation(SD) of descending aorta and muscle at the level of epibronchial were measured.CT dose index(CTDI) and dose length product(DLP) were compared.Two radiologists assessed the image quality with 5-point scale.The degree of interobserver concordance was evaluated using Kappatest.Results All images of both groups could satisfy diagnosis requirement,and the interobserver agreement for diagnosis acceptability was good(Kappavalue was 0.795).CTDI was(3.23±0.53) mGy in low-dose group,while(5.27±1.07) mGy in control group.DLP was(114.96±18.90) mGy.cm in low-dose group,while(184.40±36.85) mGy.cm in control group.The radiation dose was(1.60±0.26) mSv in low-dose group,while(2.58±0.51) mSv in control group(all P0.001).CT value of descending aorta was(39.90±8.31) HU in low-dose group and(43.12±7.43) HU in control group,SD was 13.61±2.00in low-dose group and 13.00±3.39in control group(all P0.05).CT value of muscle at the level of epibronchial was(45.50±11.85) HU in low-dose group and(48.23±10.99) HU in control group,SD was 10.34±1.55in low-dose group and 8.53±1.99in control group(all P0.05).Conclsion SAFIRE can reduce radiation dose in adult chest CT scan on the condition that the image quality was not affected.

Key concepts: Medicine, Nuclear medicine, Effective dose (radiation), Radiation dose, Radiology, Image quality, Computer science, Image (mathematics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of sinogram-affirmed iterative reconstruction technique in reducing radiation dose of chest CT examination — Research Paper | ScholarLens