Evaluation on precision of automatic coagulation analyzer CA7000 by using NCCLS EP5-A2 document

Xiumin Zhang

Open publisher page 0 citations

Abstract

Objective To evaluate the precision of the automatic coagulation analyzer CA7000.Methods The precision of prothrombin time(PT),activated partial thromboplastin time(APTT),thrombin time(TT) and fibrinogen(FIB) examined by automatic coagulation analyzer CA7000 were evaluated by NCCLS EP5-A2 document.Results For the four items(PT,APTT,TT,FIB),the within-run precision coefficients of variation were 0.54%-1.51%,0.64%-1.61%,2.87%,1.68%;the between-run precision coefficients of variation were 0.73%-3.27%,1.85%-2.06%,0%,1.98%;the between-day precision coefficients of variation were 0.98%-1.82%,0.56%-1.55%,1.94%,1.61%;the total precision coefficients of variation were 2.40%-3.63%,2.11%-2.90%,3.31%,3.06%.Conclusion The precision of PT,APTT,TT,FIB examined by automatic coagulation analyzer CA7000 can meet the requirements of clinical trials.

About this research paper

What this paper is about

Objective To evaluate the precision of the automatic coagulation analyzer CA7000.Methods The precision of prothrombin time(PT),activated partial thromboplastin time(APTT),thrombin time(TT) and fibrinogen(FIB) examined by automatic coagulation analyzer CA7000 were evaluated by NCCLS EP5-A2 document.Results For the four items(PT,APTT,TT,FIB),the within-run precision coefficients of variation were 0.54%-1.51%,0.64%-1.61%,2.87%,1.68%;the between-run precision coefficients of variation were 0.73%-3.27%,1.85%-2.06%,0%,1.98%;the between-day precision coefficients of variation were 0.98%-1.82%,0.56%-1.55%,1.94%,1.61%;the total precision coefficients of variation were 2.40%-3.63%,2.11%-2.90%,3.31%,3.06%.Conclusion The precision of PT,APTT,TT,FIB examined by automatic coagulation analyzer CA7000 can meet the requirements of clinical trials.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the precision of the automatic coagulation analyzer CA7000.Methods The precision of prothrombin time(PT),activated partial thromboplastin time(APTT),thrombin time(TT) and fibrinogen(FIB) examined by automatic coagulation analyzer CA7000 were evaluated by NCCLS EP5-A2 document.Results For the four items(PT,APTT,TT,FIB),the within-run precision coefficients of variation were 0.54%-1.51%,0.64%-1.61%,2.87%,1.68%;the between-run precision coefficients of variation were 0.73%-3.27%,1.85%-2.06%,0%,1.98%;the between-day precision coefficients of variation were 0.98%-1.82%,0.56%-1.55%,1.94%,1.61%;the total precision coefficients of variation were 2.40%-3.63%,2.11%-2.90%,3.31%,3.06%.Conclusion The precision of PT,APTT,TT,FIB examined by automatic coagulation analyzer CA7000 can meet the requirements of clinical trials.

Key concepts: Spectrum analyzer, Partial thromboplastin time, Prothrombin time, Fibrinogen, Coefficient of variation, Accuracy and precision, Coagulation, Thrombin time

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation on precision of automatic coagulation analyzer CA7000 by using NCCLS EP5-A2 document — Research Paper | ScholarLens