2011Hebei yixueRequires access

Evaluating the Detection Performance of STA-R Automatic Coagulation Analyzer

Hong Liu

Open publisher page 0 citations

Abstract

Objective: To understand the STA-R automatic coagulation analyzer basic detection performance.Method: The instrument detected the solidification of prothrombin time(PT),activated partial thromboplastin time(APTT),fibrinogen(FIB) and thrombin time(TT) four indicators,the initial performance of this instrument evaluation.Result: The instrument measured the within and day of each index were less than 5.0% CV,PT and FIB detection of the correlation coefficients were-0.992 and 0.999,carry over PT was 1.34%,APTT was 1.65%,FIB 2.94 %,TT was 0.31%.Conclusion: STA-R automatic coagulation analyzer with good linearity,high accuracy,high intra and inter-day precision and strong ability to prevent carryover,a larger sample size for clinical examination room routine work.

About this research paper

What this paper is about

Objective: To understand the STA-R automatic coagulation analyzer basic detection performance.Method: The instrument detected the solidification of prothrombin time(PT),activated partial thromboplastin time(APTT),fibrinogen(FIB) and thrombin time(TT) four indicators,the initial performance of this instrument evaluation.Result: The instrument measured the within and day of each index were less than 5.0% CV,PT and FIB detection of the correlation coefficients were-0.992 and 0.999,carry over PT was 1.34%,APTT was 1.65%,FIB 2.94 %,TT was 0.31%.Conclusion: STA-R automatic coagulation analyzer with good linearity,high accuracy,high intra and inter-day precision and strong ability to prevent carryover,a larger sample size for clinical examination room routine work.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To understand the STA-R automatic coagulation analyzer basic detection performance.Method: The instrument detected the solidification of prothrombin time(PT),activated partial thromboplastin time(APTT),fibrinogen(FIB) and thrombin time(TT) four indicators,the initial performance of this instrument evaluation.Result: The instrument measured the within and day of each index were less than 5.0% CV,PT and FIB detection of the correlation coefficients were-0.992 and 0.999,carry over PT was 1.34%,APTT was 1.65%,FIB 2.94 %,TT was 0.31%.Conclusion: STA-R automatic coagulation analyzer with good linearity,high accuracy,high intra and inter-day precision and strong ability to prevent carryover,a larger sample size for clinical examination room routine work.

Key concepts: Medicine, Spectrum analyzer, Prothrombin time, Partial thromboplastin time, Fibrinogen, Coagulation, Thrombin time, Biomedical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluating the Detection Performance of STA-R Automatic Coagulation Analyzer — Research Paper | ScholarLens