2008Food ScienceRequires access

Analysis of Organic Acids in Fermented Capsicum by Reverse Phase High Performance Liquid Chromatography

Yanfang Zhu

Open publisher page 0 citations

Abstract

A method for simultaneous determination of 8 organic acids in fermented Capsicum by reverse phase high performance liquid chromatography was developed. Hypersil-ODS2 column(4.6 mm×200 mm, 5μm)was used at 17℃ and mobile phase was 2% CH3OH-0.05 mol/L KH2PO4(pH 2.8)with flow rate of 0.8 ml/min. Detection wavelength was 214 nm. The relative standard deviations were lower than 3%, and the recoveries were 92.87% to 106.15%. In this study, two methods (extracted with heating or ultrasonic) were used to extract organic acids, it is proved that extraction with heating is better than ultrasonic.

About this research paper

What this paper is about

A method for simultaneous determination of 8 organic acids in fermented Capsicum by reverse phase high performance liquid chromatography was developed. Hypersil-ODS2 column(4.6 mm×200 mm, 5μm)was used at 17℃ and mobile phase was 2% CH3OH-0.05 mol/L KH2PO4(pH 2.8)with flow rate of 0.8 ml/min. Detection wavelength was 214 nm. The relative standard deviations were lower than 3%, and the recoveries were 92.87% to 106.15%. In this study, two methods (extracted with heating or ultrasonic) were used to extract organic acids, it is proved that extraction with heating is better than ultrasonic.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for simultaneous determination of 8 organic acids in fermented Capsicum by reverse phase high performance liquid chromatography was developed. Hypersil-ODS2 column(4.6 mm×200 mm, 5μm)was used at 17℃ and mobile phase was 2% CH3OH-0.05 mol/L KH2PO4(pH 2.8)with flow rate of 0.8 ml/min. Detection wavelength was 214 nm. The relative standard deviations were lower than 3%, and the recoveries were 92.87% to 106.15%. In this study, two methods (extracted with heating or ultrasonic) were used to extract organic acids, it is proved that extraction with heating is better than ultrasonic.

Key concepts: Chromatography, Chemistry, High-performance liquid chromatography, Extraction (chemistry), Phase (matter), Fermentation, Volumetric flow rate, Relative standard deviation

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of Organic Acids in Fermented Capsicum by Reverse Phase High Performance Liquid Chromatography — Research Paper | ScholarLens