Comparison investigation on the results of different detection system blood coagulation analyzers

Fei Li

Open publisher page 0 citations

Abstract

Objective To investigate the comparability of different detection system blood coagulation analyzers,in order to achieve the efficiency of quality control.Methods With STA compact and CA-1500 blood coagulation analyzers,the quality control material and 100 comparison blood samples(concentration covered biology reference interval) were determined.The measured results were analyzed and compared according to American Clinical Laboratory Improvement Amendment 88(CLIA′88) allowable total error 1/2 comparison and correlation(r0.975) as judgment standard.The instrument comparability and correlation were observed.Results When STA compact and CA-1500 blood coagulation analyzers measuring samples without icterus and lipaemia,the results of international normalized ratio(INR) and low-value fibrinogen(Fbg) were consistent.The relative deviation was within allowance range,and the correlation was good(r0.975).The result of activated patial thromboplastin time(APTT) correlation was fair,but the relative deviation was not allowed.The results of INR,APTT and Fbg was inconsistent when the samples was icterus or(and) lipaemia,and the relative deviation was not allowed and the correlation was bad(r0.975).Conclusions The comparability,correlation and differences can be reflected by comparing the results of different detection system blood coagulation analyzers.

About this research paper

What this paper is about

Objective To investigate the comparability of different detection system blood coagulation analyzers,in order to achieve the efficiency of quality control.Methods With STA compact and CA-1500 blood coagulation analyzers,the quality control material and 100 comparison blood samples(concentration covered biology reference interval) were determined.The measured results were analyzed and compared according to American Clinical Laboratory Improvement Amendment 88(CLIA′88) allowable total error 1/2 comparison and correlation(r0.975) as judgment standard.The instrument comparability and correlation were observed.Results When STA compact and CA-1500 blood coagulation analyzers measuring samples without icterus and lipaemia,the results of international normalized ratio(INR) and low-value fibrinogen(Fbg) were consistent.The relative deviation was within allowance range,and the correlation was good(r0.975).The result of activated patial thromboplastin time(APTT) correlation was fair,but the relative deviation was not allowed.The results of INR,APTT and Fbg was inconsistent when the samples was icterus or(and) lipaemia,and the relative deviation was not allowed and the correlation was bad(r0.975).Conclusions The comparability,correlation and differences can be reflected by comparing the results of different detection system blood coagulation analyzers.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To investigate the comparability of different detection system blood coagulation analyzers,in order to achieve the efficiency of quality control.Methods With STA compact and CA-1500 blood coagulation analyzers,the quality control material and 100 comparison blood samples(concentration covered biology reference interval) were determined.The measured results were analyzed and compared according to American Clinical Laboratory Improvement Amendment 88(CLIA′88) allowable total error 1/2 comparison and correlation(r0.975) as judgment standard.The instrument comparability and correlation were observed.Results When STA compact and CA-1500 blood coagulation analyzers measuring samples without icterus and lipaemia,the results of international normalized ratio(INR) and low-value fibrinogen(Fbg) were consistent.The relative deviation was within allowance range,and the correlation was good(r0.975).The result of activated patial thromboplastin time(APTT) correlation was fair,but the relative deviation was not allowed.The results of INR,APTT and Fbg was inconsistent when the samples was icterus or(and) lipaemia,and the relative deviation was not allowed and the correlation was bad(r0.975).Conclusions The comparability,correlation and differences can be reflected by comparing the results of different detection system blood coagulation analyzers.

Key concepts: Prothrombin time, Allowance (engineering), Partial thromboplastin time, Relative standard deviation, Medicine, Whole blood, Statistics, Correlation coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison investigation on the results of different detection system blood coagulation analyzers — Research Paper | ScholarLens