Comparison and analysis between computer optometry and retinoscopy optometry before and after children' s pupil scatter
Ruizhuang Li
Abstract
Ruizhuang Li
Abstract
Objective:To study the precision and practical value of computer optometry instrument for children' s optometry,finding out whether the computer optometry instrument can be used for children or not.Method:Pre-liminary test by TOPCON-7100computer optometry was made on257children with abnormal phototropism,and then1%of Atopin liquid medicine was dropped to eyes twice a day for three days in succession.After that,comput-er optometry and retinoscopy optometry were made separately.Result:Before pupil scatter,there was much differ-ence in the average value from lens between computer optometry and retinoscopy optometry.(P0.05);after pupil scatter,the average value from lens of computer optometry had close relativity to that of retinoscopy optometry and the average value from column lens(r=0.971,r=0.801).The difference was not significant(P0.05).The difference in the column lens axis between computer optometry and retinoscopy optometry was quite big(P0.05).Conclu-sion:computer optometry instrument cannot replace retinoscopy optometry,but can be used as instant secondary tool for medical examination.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To study the precision and practical value of computer optometry instrument for children' s optometry,finding out whether the computer optometry instrument can be used for children or not.Method:Pre-liminary test by TOPCON-7100computer optometry was made on257children with abnormal phototropism,and then1%of Atopin liquid medicine was dropped to eyes twice a day for three days in succession.After that,comput-er optometry and retinoscopy optometry were made separately.Result:Before pupil scatter,there was much differ-ence in the average value from lens between computer optometry and retinoscopy optometry.(P0.05);after pupil scatter,the average value from lens of computer optometry had close relativity to that of retinoscopy optometry and the average value from column lens(r=0.971,r=0.801).The difference was not significant(P0.05).The difference in the column lens axis between computer optometry and retinoscopy optometry was quite big(P0.05).Conclu-sion:computer optometry instrument cannot replace retinoscopy optometry,but can be used as instant secondary tool for medical examination.
Key concepts: Retinoscopy, Optometry, Pupil, Medicine, Ophthalmology, Refractive error, Eye disease, Optics