Study on the Relationship Between Magnitude Deviation of Near Earthquakes and Calibration Function in Jiangxi Digital Seismic Network
Xie Caimei
Abstract
Xie Caimei
Abstract
To calculate the deviations between single station magnitudes and average ones,the paper selected 138 ML≥1.5 earthquake events recorded on Jiangxi Digital Seismic Network from October 2007 to December 2009.The magnitude deviations of earthquake is analyzed on the frequency distribution,calibration function and average period quantitatively and statistically.The results show: 1) The magnitude deviations at all stations are relatively small,except at Jiujiang,Ganzhou,Shicheng,Duchang and Gaoan stations.2) The deviation of calibration function currently used is larger when the epicentral distance is less than 40 km or more than 330 km,and the corrections of calibration function are given in this paper.3) The deviations between single station magnitudes and average ones become very unstable when average period is larger than 0.17s,which is possibly due to undersampling that epicentral distance of single station is more than 300 km.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
To calculate the deviations between single station magnitudes and average ones,the paper selected 138 ML≥1.5 earthquake events recorded on Jiangxi Digital Seismic Network from October 2007 to December 2009.The magnitude deviations of earthquake is analyzed on the frequency distribution,calibration function and average period quantitatively and statistically.The results show: 1) The magnitude deviations at all stations are relatively small,except at Jiujiang,Ganzhou,Shicheng,Duchang and Gaoan stations.2) The deviation of calibration function currently used is larger when the epicentral distance is less than 40 km or more than 330 km,and the corrections of calibration function are given in this paper.3) The deviations between single station magnitudes and average ones become very unstable when average period is larger than 0.17s,which is possibly due to undersampling that epicentral distance of single station is more than 300 km.
Key concepts: Magnitude (astronomy), Calibration, Seismology, Geology, Geodesy, Undersampling, Standard deviation, Earthquake magnitude