2003•Physical Testing and Chemical AnalysisRequires access

AXIAL-VIEW ICP-AES DETERMINATION OF Pb Cu As Cd Cr AND Co IN TEA

Shi YuanZhi, Lifeng Ma

Open publisher page 0 citations

Abstract

Optimum conditions of simultaneous determination of Pb Cu As Cd Cr and Co in tea by ICP-AES were studied. Working parameters of the instrument were described in detail. It was shown that the results obtained by digestion of samples with micro-wave heating were better in accuracy and precision than by the dry-ashing method. The suitable acidity of the sample solution was found to be in the range 0.22mol·L~(-1) to 1.76mol·L~(-1) of HNO_3. RSD's (n=5) obtained were in the range 0.1%~8.3%, and recoveries were in the range 90%~104%, for all these elements. The proposed method has been used in the analysis of CRM (GBW07605—GSV—4) giving results consistent with the certified values.

About this research paper

What this paper is about

Optimum conditions of simultaneous determination of Pb Cu As Cd Cr and Co in tea by ICP-AES were studied. Working parameters of the instrument were described in detail. It was shown that the results obtained by digestion of samples with micro-wave heating were better in accuracy and precision than by the dry-ashing method. The suitable acidity of the sample solution was found to be in the range 0.22mol·L~(-1) to 1.76mol·L~(-1) of HNO_3. RSD's (n=5) obtained were in the range 0.1%~8.3%, and recoveries were in the range 90%~104%, for all these elements. The proposed method has been used in the analysis of CRM (GBW07605—GSV—4) giving results consistent with the certified values.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Optimum conditions of simultaneous determination of Pb Cu As Cd Cr and Co in tea by ICP-AES were studied. Working parameters of the instrument were described in detail. It was shown that the results obtained by digestion of samples with micro-wave heating were better in accuracy and precision than by the dry-ashing method. The suitable acidity of the sample solution was found to be in the range 0.22mol·L~(-1) to 1.76mol·L~(-1) of HNO_3. RSD's (n=5) obtained were in the range 0.1%~8.3%, and recoveries were in the range 90%~104%, for all these elements. The proposed method has been used in the analysis of CRM (GBW07605—GSV—4) giving results consistent with the certified values.

Key concepts: Ashing, Inductively coupled plasma atomic emission spectroscopy, Analytical Chemistry (journal), Chemistry, Certified reference materials, Inductively coupled plasma, Chromatography, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
AXIAL-VIEW ICP-AES DETERMINATION OF Pb Cu As Cd Cr AND Co IN TEA — Research Paper | ScholarLens