2007Physical Testing and Chemical AnalysisRequires access

ICP-AES Determination of Lead,Cadmium,Chromium and Arsenic in Industrial Waste Water

Ruan Yi

Open publisher page 0 citations

Abstract

ICP-AES was applied to simultaneous determination of Pb,Cd,Cr and As in industrial waste water.Working conditions of the instrument and choice of analytical spectral lines for the elements were tested and optimized.Values of detection limit were found to be 0.008,0.002,0.007, 0.015 mg·L-1 for Pb,Cd,Cr and As respectively.Precision of the method were tested at the concentration levels of 0.489 mg·L-1(for Pb),0.086 6 mg·L-1(for Cd),0.231 mg·L-1(for Cr) and 0.395 mg·L-1(for As) for 8 determinations,and values of RSD′s obtained were 1.71%,1.22%,0.95% and 1.40% respectively.Tests for recovery were made by the standard addition method on the base of 2 waste water samples,values of recovery found were in the range from 95.4% to 104.6%.

About this research paper

What this paper is about

ICP-AES was applied to simultaneous determination of Pb,Cd,Cr and As in industrial waste water.Working conditions of the instrument and choice of analytical spectral lines for the elements were tested and optimized.Values of detection limit were found to be 0.008,0.002,0.007, 0.015 mg·L-1 for Pb,Cd,Cr and As respectively.Precision of the method were tested at the concentration levels of 0.489 mg·L-1(for Pb),0.086 6 mg·L-1(for Cd),0.231 mg·L-1(for Cr) and 0.395 mg·L-1(for As) for 8 determinations,and values of RSD′s obtained were 1.71%,1.22%,0.95% and 1.40% respectively.Tests for recovery were made by the standard addition method on the base of 2 waste water samples,values of recovery found were in the range from 95.4% to 104.6%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

ICP-AES was applied to simultaneous determination of Pb,Cd,Cr and As in industrial waste water.Working conditions of the instrument and choice of analytical spectral lines for the elements were tested and optimized.Values of detection limit were found to be 0.008,0.002,0.007, 0.015 mg·L-1 for Pb,Cd,Cr and As respectively.Precision of the method were tested at the concentration levels of 0.489 mg·L-1(for Pb),0.086 6 mg·L-1(for Cd),0.231 mg·L-1(for Cr) and 0.395 mg·L-1(for As) for 8 determinations,and values of RSD′s obtained were 1.71%,1.22%,0.95% and 1.40% respectively.Tests for recovery were made by the standard addition method on the base of 2 waste water samples,values of recovery found were in the range from 95.4% to 104.6%.

Key concepts: Arsenic, Cadmium, Detection limit, Chromium, Chemistry, Inductively coupled plasma atomic emission spectroscopy, Environmental chemistry, Wastewater

Related papers

Back to paper searchBrowse research topicsOriginal source
ICP-AES Determination of Lead,Cadmium,Chromium and Arsenic in Industrial Waste Water — Research Paper | ScholarLens