2006Chemical engineerRequires access

Determination of phosphate in wastewater by flow injection spectrophotometry

Haitao Zhang

Open publisher page 0 citations

Abstract

A method for determination of phosphate in water samples by using flow injection spectrophotometry and modification the preparation of ascorbic acid was described in this paper.Moreover,effects of concentration of reagents and other condition had been optimized.A detection limit of 0.01mg·L~(-1) was achieved at a sampling frequency of 72·h~(-1).The relative standard deviation was 0.9% for the determination of 0.5mg·L~(-1)(n=11).The proposed method was successfully applied to the analyses of several wastewaters.

About this research paper

What this paper is about

A method for determination of phosphate in water samples by using flow injection spectrophotometry and modification the preparation of ascorbic acid was described in this paper.Moreover,effects of concentration of reagents and other condition had been optimized.A detection limit of 0.01mg·L~(-1) was achieved at a sampling frequency of 72·h~(-1).The relative standard deviation was 0.9% for the determination of 0.5mg·L~(-1)(n=11).The proposed method was successfully applied to the analyses of several wastewaters.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for determination of phosphate in water samples by using flow injection spectrophotometry and modification the preparation of ascorbic acid was described in this paper.Moreover,effects of concentration of reagents and other condition had been optimized.A detection limit of 0.01mg·L~(-1) was achieved at a sampling frequency of 72·h~(-1).The relative standard deviation was 0.9% for the determination of 0.5mg·L~(-1)(n=11).The proposed method was successfully applied to the analyses of several wastewaters.

Key concepts: Spectrophotometry, Detection limit, Relative standard deviation, Chromatography, Ascorbic acid, Chemistry, Reagent, Wastewater

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of phosphate in wastewater by flow injection spectrophotometry — Research Paper | ScholarLens