2012Anhui nongye kexueRequires access

Determination of Phosphate in Environmental Samples by Sequential Injection Micro-sampling On-line Dilution Spectrophotometry

Yongqiang Liu, Tao Guan-hong, Wang Jiazi, MA Zuobing

Open publisher page 0 citations

Abstract

[Objective] The aim was to study the feasibility of using sequential injection micro-sampling on-line dilution spectrophotometry determining phosphate in environmental samples.[Method] A sequence injection analysis method for the direct determination of phosphate in environmental samples with on-line intelligent dilution and photometric detection was described.Phosphate was performed by the molybdenum blue method with detection at 720 nm.[Result] At the optimized condition,the calibration graph is a linear when PO43-concentration was in range of 1-6 and 6-50 mg/L.The relative standard deviation is 1.4 % for the determination of 2 mg/L PO43-(n=11) and 1.6% for the determination of 20 mg/L PO43-(n=11).[Conclusion] It is characterized by high automation and wide analytical working range,which meets the requirements of automatic analysis and on-line monitoring.

About this research paper

What this paper is about

[Objective] The aim was to study the feasibility of using sequential injection micro-sampling on-line dilution spectrophotometry determining phosphate in environmental samples.[Method] A sequence injection analysis method for the direct determination of phosphate in environmental samples with on-line intelligent dilution and photometric detection was described.Phosphate was performed by the molybdenum blue method with detection at 720 nm.[Result] At the optimized condition,the calibration graph is a linear when PO43-concentration was in range of 1-6 and 6-50 mg/L.The relative standard deviation is 1.4 % for the determination of 2 mg/L PO43-(n=11) and 1.6% for the determination of 20 mg/L PO43-(n=11).[Conclusion] It is characterized by high automation and wide analytical working range,which meets the requirements of automatic analysis and on-line monitoring.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] The aim was to study the feasibility of using sequential injection micro-sampling on-line dilution spectrophotometry determining phosphate in environmental samples.[Method] A sequence injection analysis method for the direct determination of phosphate in environmental samples with on-line intelligent dilution and photometric detection was described.Phosphate was performed by the molybdenum blue method with detection at 720 nm.[Result] At the optimized condition,the calibration graph is a linear when PO43-concentration was in range of 1-6 and 6-50 mg/L.The relative standard deviation is 1.4 % for the determination of 2 mg/L PO43-(n=11) and 1.6% for the determination of 20 mg/L PO43-(n=11).[Conclusion] It is characterized by high automation and wide analytical working range,which meets the requirements of automatic analysis and on-line monitoring.

Key concepts: Molybdenum blue, Dilution, Spectrophotometry, Phosphate, Chromatography, Relative standard deviation, Chemistry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Phosphate in Environmental Samples by Sequential Injection Micro-sampling On-line Dilution Spectrophotometry — Research Paper | ScholarLens