2013Lishizhen Medicine and Materia Medica ResearchRequires access

Determination of Matrine and Oxymatrine in the Crude Extract of Sophora flavescens by HPLC

Xiuhong Wu

Open publisher page 0 citations

Abstract

Objective To develop a method for determinition matrine and oxymatrine of crude extract of Sophora flavescens. Methods AichromBond-AQ C18 column(4.6 mm×250 mm,5 μm)was used as the solid phase.Methanol-0.05% triethylamine solution(70:30,V/V)was taken as mobile phase.The flow rate was 1.00 ml/min.The UV detection wavelength was 215 nm. Results The calibration curves of matrine and oxymatrine were linear in the range of 0.02~160 mg/L and 0.04~100 mg/L,respectively.The average recoveries of both were 98.59% and 99.43%,respectively. Conclusion The method established method is sensitive,simple,and accurate.

About this research paper

What this paper is about

Objective To develop a method for determinition matrine and oxymatrine of crude extract of Sophora flavescens. Methods AichromBond-AQ C18 column(4.6 mm×250 mm,5 μm)was used as the solid phase.Methanol-0.05% triethylamine solution(70:30,V/V)was taken as mobile phase.The flow rate was 1.00 ml/min.The UV detection wavelength was 215 nm. Results The calibration curves of matrine and oxymatrine were linear in the range of 0.02~160 mg/L and 0.04~100 mg/L,respectively.The average recoveries of both were 98.59% and 99.43%,respectively. Conclusion The method established method is sensitive,simple,and accurate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a method for determinition matrine and oxymatrine of crude extract of Sophora flavescens. Methods AichromBond-AQ C18 column(4.6 mm×250 mm,5 μm)was used as the solid phase.Methanol-0.05% triethylamine solution(70:30,V/V)was taken as mobile phase.The flow rate was 1.00 ml/min.The UV detection wavelength was 215 nm. Results The calibration curves of matrine and oxymatrine were linear in the range of 0.02~160 mg/L and 0.04~100 mg/L,respectively.The average recoveries of both were 98.59% and 99.43%,respectively. Conclusion The method established method is sensitive,simple,and accurate.

Key concepts: Oxymatrine, Matrine, Sophora flavescens, Chromatography, Chemistry, Triethylamine, Sophora, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Matrine and Oxymatrine in the Crude Extract of Sophora flavescens by HPLC — Research Paper | ScholarLens