Determination of Astragaloside IV and paeoniflorin in total glucosides of Buyang Huanwu decoction by HPLC
Chang-Qing Deng
Abstract
Chang-Qing Deng
Abstract
Objective To establish the HPLC conditions for determination of Astragaloside Ⅳ and paeoniflorin in total glucosides of Buyang Huanwu decoction.Methods The Kromasil C18 column(250 mm×4.6 mm,5μm) was used.Astragaloside Ⅳ detection conditions:Evaporative light scattering detector was used;the mobile phase was methanol-water(80:20)(v/v);temperature of drift tube was 60 ℃;gas flow rate was 1.5 L/min;pressure was 0.5 Mpa and column temperature was 30 ℃.Paeoniflorin detection conditions:the mobile phase was methanol-water(23:77)(v/v);the flow rate was 1.0 mL/min;the detection wavelength was 218 nm and column temperature was 30 ℃.Results Astragaloside IV was better in linear correlation between 0.57~9.10 μg,Y=1.5063X +2.4096,(r=0.9994).Paeoniflorin was better in linear correlation between 0.48~7.70 μg,Y=598.91X-2.3346(r=0.9999).The average recoveries were 99.62% and 101.3% respectively,and RSD were 2.6% and 1.7%(n=6) respectively.Conclusion The method is rapid,simple and accurate and has high sensitivity for determination of Astragaloside Ⅳ and paeoniflorin,which can provide quality standards for the study of total glycosides.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To establish the HPLC conditions for determination of Astragaloside Ⅳ and paeoniflorin in total glucosides of Buyang Huanwu decoction.Methods The Kromasil C18 column(250 mm×4.6 mm,5μm) was used.Astragaloside Ⅳ detection conditions:Evaporative light scattering detector was used;the mobile phase was methanol-water(80:20)(v/v);temperature of drift tube was 60 ℃;gas flow rate was 1.5 L/min;pressure was 0.5 Mpa and column temperature was 30 ℃.Paeoniflorin detection conditions:the mobile phase was methanol-water(23:77)(v/v);the flow rate was 1.0 mL/min;the detection wavelength was 218 nm and column temperature was 30 ℃.Results Astragaloside IV was better in linear correlation between 0.57~9.10 μg,Y=1.5063X +2.4096,(r=0.9994).Paeoniflorin was better in linear correlation between 0.48~7.70 μg,Y=598.91X-2.3346(r=0.9999).The average recoveries were 99.62% and 101.3% respectively,and RSD were 2.6% and 1.7%(n=6) respectively.Conclusion The method is rapid,simple and accurate and has high sensitivity for determination of Astragaloside Ⅳ and paeoniflorin,which can provide quality standards for the study of total glycosides.
Key concepts: Paeoniflorin, Astragaloside, Chromatography, Chemistry, High-performance liquid chromatography, Decoction, Radix (gastropod), Linear correlation