Determination of ginsenoside R_e in total ginsenoside from stalk and leaf of Panax ginseng
Hailiang Xin
Abstract
Hailiang Xin
Abstract
Objective: To determine quantitatively ginsenoside Re in total ginsenoside from stalk and leaf of Panax ginseng,and to provide experimental evident for total ginsenoside quality control of Panax ginseng.Methods:The method was developed with the condition as follows:Diamonsil C18(4.6 mm×25 mm,5 μm) and DIKMA EasyGuard C18(10 mm×4.6 mm) was used as chromatographic column and guard column respectively.Gradient elution was employed with the mobile phase of acetonitrile-0.5% acetic acid/water at a flow rate of 1.25 mL/min.ELSD:temperature of the drift tube 40 ℃;gas pressure: 3.4 bar;gain: 7.Results:The standard curve: C=1.191×10-7A-0.187 6;the linear range: 0.038~1.14 mg/mL,r=0.999 3;the limits of detection: 20 ng(S/N3);recovery rate of the added sample: 96.84%~104.21%.Conclusion:With its accuracy,sensitivity,reproducibility as well as the simplicity of sample preparation,this method is feasible for quality control of total ginsenoside from stalk and leaf of Panax ginseng.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To determine quantitatively ginsenoside Re in total ginsenoside from stalk and leaf of Panax ginseng,and to provide experimental evident for total ginsenoside quality control of Panax ginseng.Methods:The method was developed with the condition as follows:Diamonsil C18(4.6 mm×25 mm,5 μm) and DIKMA EasyGuard C18(10 mm×4.6 mm) was used as chromatographic column and guard column respectively.Gradient elution was employed with the mobile phase of acetonitrile-0.5% acetic acid/water at a flow rate of 1.25 mL/min.ELSD:temperature of the drift tube 40 ℃;gas pressure: 3.4 bar;gain: 7.Results:The standard curve: C=1.191×10-7A-0.187 6;the linear range: 0.038~1.14 mg/mL,r=0.999 3;the limits of detection: 20 ng(S/N3);recovery rate of the added sample: 96.84%~104.21%.Conclusion:With its accuracy,sensitivity,reproducibility as well as the simplicity of sample preparation,this method is feasible for quality control of total ginsenoside from stalk and leaf of Panax ginseng.
Key concepts: Ginseng, Chemistry, Chromatography, Ginsenoside Rg1, Ginsenoside, Chromatography detector, Araliaceae, Gradient elution