2010Xihua Daxue xuebao. Zhexue shehui kexue banRequires access

Content Determination of Tanshinone IIA in Danqishujin Pills

Yuxin He

Open publisher page 1 citations

Abstract

To establish a method for the content determination of Tanshinone ⅡA in Danqishujin Pills,HPLC was adopted with a Kromasil-C18(200mm×4.6mm,5μm)column.The mobile phase consisted of methanol-water(75:25) and the detecting wavelength was set at 270nm.The flow rate was 1.0ml·min-1 with column temperature of 35℃.The linear range of Tanshinone ⅡA was 0.020~0.200μg(r=0.9999),and the average recovery was 99.06% with RSD of 0.80%(n=6).The method is considered to be convenient and accurate with good reproducibility,so it is suitable to the content determination of tanshinone ⅡA in danqishujin pills.

About this research paper

What this paper is about

To establish a method for the content determination of Tanshinone ⅡA in Danqishujin Pills,HPLC was adopted with a Kromasil-C18(200mm×4.6mm,5μm)column.The mobile phase consisted of methanol-water(75:25) and the detecting wavelength was set at 270nm.The flow rate was 1.0ml·min-1 with column temperature of 35℃.The linear range of Tanshinone ⅡA was 0.020~0.200μg(r=0.9999),and the average recovery was 99.06% with RSD of 0.80%(n=6).The method is considered to be convenient and accurate with good reproducibility,so it is suitable to the content determination of tanshinone ⅡA in danqishujin pills.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To establish a method for the content determination of Tanshinone ⅡA in Danqishujin Pills,HPLC was adopted with a Kromasil-C18(200mm×4.6mm,5μm)column.The mobile phase consisted of methanol-water(75:25) and the detecting wavelength was set at 270nm.The flow rate was 1.0ml·min-1 with column temperature of 35℃.The linear range of Tanshinone ⅡA was 0.020~0.200μg(r=0.9999),and the average recovery was 99.06% with RSD of 0.80%(n=6).The method is considered to be convenient and accurate with good reproducibility,so it is suitable to the content determination of tanshinone ⅡA in danqishujin pills.

Key concepts: Chromatography, Reproducibility, Linear range, Content determination, High-performance liquid chromatography, Chemistry, Analytical Chemistry (journal), Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Content Determination of Tanshinone IIA in Danqishujin Pills — Research Paper | ScholarLens