2010Anhui Chemical IndustryRequires access

Treatment of Oily Wastewater by E-Fenton Technique

Gao Xiang

Open publisher page 0 citations

Abstract

In this paper the treatment of oily wastewater E-Fenton reagent was studied.The experiment proved the order of factors affecting removal rate is:the pH,the voltage,the reaction time,the concentration of oily wastewater,and concentration of Na2SO4.The optimum operation parameters were determined by single factor analysis as follows:under the room temperature,the pH is 2.5,the voltage is 10V,the reaction time is 60 mins,the concentration of oily wastewater is 100mg/L,and concentration of Na2SO4 is 30 mg/L.Under the optimum reaction conditions,the removal rate of oil is 50.5%.

About this research paper

What this paper is about

In this paper the treatment of oily wastewater E-Fenton reagent was studied.The experiment proved the order of factors affecting removal rate is:the pH,the voltage,the reaction time,the concentration of oily wastewater,and concentration of Na2SO4.The optimum operation parameters were determined by single factor analysis as follows:under the room temperature,the pH is 2.5,the voltage is 10V,the reaction time is 60 mins,the concentration of oily wastewater is 100mg/L,and concentration of Na2SO4 is 30 mg/L.Under the optimum reaction conditions,the removal rate of oil is 50.5%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper the treatment of oily wastewater E-Fenton reagent was studied.The experiment proved the order of factors affecting removal rate is:the pH,the voltage,the reaction time,the concentration of oily wastewater,and concentration of Na2SO4.The optimum operation parameters were determined by single factor analysis as follows:under the room temperature,the pH is 2.5,the voltage is 10V,the reaction time is 60 mins,the concentration of oily wastewater is 100mg/L,and concentration of Na2SO4 is 30 mg/L.Under the optimum reaction conditions,the removal rate of oil is 50.5%.

Key concepts: Wastewater, Reagent, Chemistry, Chromatography, Pulp and paper industry, Waste management, Environmental engineering, Environmental science