2008•Liaoning zhongyi zazhiRequires access

Determination of Paeoniflorin Content in Naoxueshuan Tablet

Xiaoyu Zhang

Open publisher page 0 citations

Abstract

Objective:To establish a HPLC method for determination of paeoniflorin content in Naoxueshuan tablet.Methods:HPLC was used with the Diamonsil C18 column(4.6 mm×150 mm,5μm),Acetonitrile-water(14∶86) as mobile phase,flow rate 1.0 mL/min.The detective wave-length was 230 nm.Results:It had a good linearity within 0.2432~1.2160μg for paeoniflorin.The average recoveries was 98.6%(n=5) and relative standard deviation(RSD) was 1.8%.Conclusion:This method is specific with accuate and reliable results,which can be used to control the quality of the products effectively.

About this research paper

What this paper is about

Objective:To establish a HPLC method for determination of paeoniflorin content in Naoxueshuan tablet.Methods:HPLC was used with the Diamonsil C18 column(4.6 mm×150 mm,5μm),Acetonitrile-water(14∶86) as mobile phase,flow rate 1.0 mL/min.The detective wave-length was 230 nm.Results:It had a good linearity within 0.2432~1.2160μg for paeoniflorin.The average recoveries was 98.6%(n=5) and relative standard deviation(RSD) was 1.8%.Conclusion:This method is specific with accuate and reliable results,which can be used to control the quality of the products effectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a HPLC method for determination of paeoniflorin content in Naoxueshuan tablet.Methods:HPLC was used with the Diamonsil C18 column(4.6 mm×150 mm,5μm),Acetonitrile-water(14∶86) as mobile phase,flow rate 1.0 mL/min.The detective wave-length was 230 nm.Results:It had a good linearity within 0.2432~1.2160μg for paeoniflorin.The average recoveries was 98.6%(n=5) and relative standard deviation(RSD) was 1.8%.Conclusion:This method is specific with accuate and reliable results,which can be used to control the quality of the products effectively.

Key concepts: Paeoniflorin, Medicine, Chromatography, High-performance liquid chromatography, Relative standard deviation, Content determination, Chemistry, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Paeoniflorin Content in Naoxueshuan Tablet — Research Paper | ScholarLens