2013Physical Testing and Chemical AnalysisRequires access

AFS Determination of Arsenic,Antimony and Mercury in Leather and Its Products with Microwave Assisted Sample Digestion

Zhu ZhongWu

Open publisher page 0 citations

Abstract

AFS was applied to the determination of As,Sb and Hg in leather and its products.The sample was digested with mixed solution of HNO3-H2O2,and reduced with mixed solution of thiourea and ascorbic acid.Hydrides of the 3 elements were generated from acidic solution using NaBH4 solution(dissolved in NaOH solution) as reducing reagent.Flow-rates of the carrier gas selected were 300 mL·min-1 for As and 400 mL·min-1 for Sb and Hg.Linear relationships between values of fluorescence intensity and mass concentration of the 3 elements were found in definite ranges,with detection limits(3s/k) of 0.22 μg·L-1(for As),0.16 μg·L-1(for Sb) and 0.04 μg·L-1(for Hg).The proposed method was applied to the analysis of leather and its products,giving values of recovery in the range of 94.0%-107% with RSD′s(n=5) less than 10%.

About this research paper

What this paper is about

AFS was applied to the determination of As,Sb and Hg in leather and its products.The sample was digested with mixed solution of HNO3-H2O2,and reduced with mixed solution of thiourea and ascorbic acid.Hydrides of the 3 elements were generated from acidic solution using NaBH4 solution(dissolved in NaOH solution) as reducing reagent.Flow-rates of the carrier gas selected were 300 mL·min-1 for As and 400 mL·min-1 for Sb and Hg.Linear relationships between values of fluorescence intensity and mass concentration of the 3 elements were found in definite ranges,with detection limits(3s/k) of 0.22 μg·L-1(for As),0.16 μg·L-1(for Sb) and 0.04 μg·L-1(for Hg).The proposed method was applied to the analysis of leather and its products,giving values of recovery in the range of 94.0%-107% with RSD′s(n=5) less than 10%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AFS was applied to the determination of As,Sb and Hg in leather and its products.The sample was digested with mixed solution of HNO3-H2O2,and reduced with mixed solution of thiourea and ascorbic acid.Hydrides of the 3 elements were generated from acidic solution using NaBH4 solution(dissolved in NaOH solution) as reducing reagent.Flow-rates of the carrier gas selected were 300 mL·min-1 for As and 400 mL·min-1 for Sb and Hg.Linear relationships between values of fluorescence intensity and mass concentration of the 3 elements were found in definite ranges,with detection limits(3s/k) of 0.22 μg·L-1(for As),0.16 μg·L-1(for Sb) and 0.04 μg·L-1(for Hg).The proposed method was applied to the analysis of leather and its products,giving values of recovery in the range of 94.0%-107% with RSD′s(n=5) less than 10%.

Key concepts: Arsenic, Reagent, Chemistry, Antimony, Thiourea, Ascorbic acid, Mercury (programming language), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
AFS Determination of Arsenic,Antimony and Mercury in Leather and Its Products with Microwave Assisted Sample Digestion — Research Paper | ScholarLens