2010Physical Testing and Chemical AnalysisRequires access

AFS Determination of Arsenic and Antimony in Soil with Microwave Assisted Sample Digestion

Xu Yun

Open publisher page 0 citations

Abstract

AFS was applied to the determination of arsenic and antimony in soil.The sample was first treated with a mixed acid of HCl+HNO3+H2O(3+1+4) for 30 min at room temperature and then digested in the microwave digestor under the prescribed program.A mixed solution of thiourea and ascorbic acid was added to the sample solution which was used for AFS determination after diluting to 10.0 mL.A aliquot of 2 mL of the supernatant sample solution was injected into the reactor to react with the reductant(KBH4 solution) and the hydrides of arsenic and antimony were carried over into the quartz atomizer by argon.Details of working condition of the AFS instrument were given.Values of detection limit(3S/N) for both As and Sb were found same as 0.050 μg·L-1.Recovery of the method was tested at 3 concentration levels by adding standard solutions of As and Sb to a soil sample as matrix,values of recovery found were in the ranges of 99.5% to 104.0%(for As) and 98.5% to 99.5%(for Sb).

About this research paper

What this paper is about

AFS was applied to the determination of arsenic and antimony in soil.The sample was first treated with a mixed acid of HCl+HNO3+H2O(3+1+4) for 30 min at room temperature and then digested in the microwave digestor under the prescribed program.A mixed solution of thiourea and ascorbic acid was added to the sample solution which was used for AFS determination after diluting to 10.0 mL.A aliquot of 2 mL of the supernatant sample solution was injected into the reactor to react with the reductant(KBH4 solution) and the hydrides of arsenic and antimony were carried over into the quartz atomizer by argon.Details of working condition of the AFS instrument were given.Values of detection limit(3S/N) for both As and Sb were found same as 0.050 μg·L-1.Recovery of the method was tested at 3 concentration levels by adding standard solutions of As and Sb to a soil sample as matrix,values of recovery found were in the ranges of 99.5% to 104.0%(for As) and 98.5% to 99.5%(for Sb).

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AFS was applied to the determination of arsenic and antimony in soil.The sample was first treated with a mixed acid of HCl+HNO3+H2O(3+1+4) for 30 min at room temperature and then digested in the microwave digestor under the prescribed program.A mixed solution of thiourea and ascorbic acid was added to the sample solution which was used for AFS determination after diluting to 10.0 mL.A aliquot of 2 mL of the supernatant sample solution was injected into the reactor to react with the reductant(KBH4 solution) and the hydrides of arsenic and antimony were carried over into the quartz atomizer by argon.Details of working condition of the AFS instrument were given.Values of detection limit(3S/N) for both As and Sb were found same as 0.050 μg·L-1.Recovery of the method was tested at 3 concentration levels by adding standard solutions of As and Sb to a soil sample as matrix,values of recovery found were in the ranges of 99.5% to 104.0%(for As) and 98.5% to 99.5%(for Sb).

Key concepts: Arsenic, Antimony, Thiourea, Detection limit, Chemistry, Matrix (chemical analysis), Ascorbic acid, Standard solution

Related papers

Back to paper searchBrowse research topicsOriginal source
AFS Determination of Arsenic and Antimony in Soil with Microwave Assisted Sample Digestion — Research Paper | ScholarLens