2012Physical Testing and Chemical AnalysisRequires access

AFS Determination of Pb,As and Hg in Crude Oil with Microwave Assisted Sample Digestion

Pan Yi-long

Open publisher page 0 citations

Abstract

AFS was applied to the determination of Pb,As and Hg in crude oil.The sample was digested with mixed solution of HNO3-H2O2(10+2),and thiourea solution was added to the sample solution as pre-reductant and KBH4 solution(dissolved in KOH solution) as reductant.Flow-rates of 300 mL·min-1 for carrier gas and 800 mL·min-1 for shielding gas were taken in the analysis.Linear relationships between values of fluorescence intensity and mass concentration of Pb,As and Hg found were in the ranges of 2.0-80.0,2.0-100.0 and 1.0-20.0 μg·L-1,with detection limit(3S/N) of 0.05,0.05 and 0.01 mg·kg-1 respectively.The proposed method was applied to the analysis of samples of crude oil,giving values of recovery in the ranges of 103%-115% for Pb,87.5%-92.1% for As and 87.5%-102% for Hg.

About this research paper

What this paper is about

AFS was applied to the determination of Pb,As and Hg in crude oil.The sample was digested with mixed solution of HNO3-H2O2(10+2),and thiourea solution was added to the sample solution as pre-reductant and KBH4 solution(dissolved in KOH solution) as reductant.Flow-rates of 300 mL·min-1 for carrier gas and 800 mL·min-1 for shielding gas were taken in the analysis.Linear relationships between values of fluorescence intensity and mass concentration of Pb,As and Hg found were in the ranges of 2.0-80.0,2.0-100.0 and 1.0-20.0 μg·L-1,with detection limit(3S/N) of 0.05,0.05 and 0.01 mg·kg-1 respectively.The proposed method was applied to the analysis of samples of crude oil,giving values of recovery in the ranges of 103%-115% for Pb,87.5%-92.1% for As and 87.5%-102% for Hg.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AFS was applied to the determination of Pb,As and Hg in crude oil.The sample was digested with mixed solution of HNO3-H2O2(10+2),and thiourea solution was added to the sample solution as pre-reductant and KBH4 solution(dissolved in KOH solution) as reductant.Flow-rates of 300 mL·min-1 for carrier gas and 800 mL·min-1 for shielding gas were taken in the analysis.Linear relationships between values of fluorescence intensity and mass concentration of Pb,As and Hg found were in the ranges of 2.0-80.0,2.0-100.0 and 1.0-20.0 μg·L-1,with detection limit(3S/N) of 0.05,0.05 and 0.01 mg·kg-1 respectively.The proposed method was applied to the analysis of samples of crude oil,giving values of recovery in the ranges of 103%-115% for Pb,87.5%-92.1% for As and 87.5%-102% for Hg.

Key concepts: Detection limit, Thiourea, Chemistry, Analytical Chemistry (journal), Crude oil, Mass concentration (chemistry), Chromatography, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
AFS Determination of Pb,As and Hg in Crude Oil with Microwave Assisted Sample Digestion — Research Paper | ScholarLens