2006Journal of Jilin Institute of Chemical TechnologyRequires access

Determination of vanillin in imprinted polymer's solution by the method of high performance liquid chromatography

Kang Kai

Open publisher page 0 citations

Abstract

The vanillin in imprinted polymer's solution has been determined on a SpherisorbC18 column using methanol-water-acetic acid as mobile phase by the method of High Performance Liquid Chromatography-UV(HPLC-UV).The calibration curves are good linear over the range of 0.0096~0.0578mg/mL with the correlation coefficient of 0.9993,and the RSD is less than 6.75%.The recovery of the method ranges from 98.2% to 112.2%.And the limit of detection(S/N=3) is 2.09μg/mL,the limit of quantification(S/N=10) is 6.93μg/mL.

About this research paper

What this paper is about

The vanillin in imprinted polymer's solution has been determined on a SpherisorbC18 column using methanol-water-acetic acid as mobile phase by the method of High Performance Liquid Chromatography-UV(HPLC-UV).The calibration curves are good linear over the range of 0.0096~0.0578mg/mL with the correlation coefficient of 0.9993,and the RSD is less than 6.75%.The recovery of the method ranges from 98.2% to 112.2%.And the limit of detection(S/N=3) is 2.09μg/mL,the limit of quantification(S/N=10) is 6.93μg/mL.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The vanillin in imprinted polymer's solution has been determined on a SpherisorbC18 column using methanol-water-acetic acid as mobile phase by the method of High Performance Liquid Chromatography-UV(HPLC-UV).The calibration curves are good linear over the range of 0.0096~0.0578mg/mL with the correlation coefficient of 0.9993,and the RSD is less than 6.75%.The recovery of the method ranges from 98.2% to 112.2%.And the limit of detection(S/N=3) is 2.09μg/mL,the limit of quantification(S/N=10) is 6.93μg/mL.

Key concepts: Vanillin, Chromatography, Detection limit, Calibration curve, High-performance liquid chromatography, Molecularly imprinted polymer, Acetic acid, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of vanillin in imprinted polymer's solution by the method of high performance liquid chromatography — Research Paper | ScholarLens