2006•Pharmaceutical Care and ResearchRequires access

Determination of 18 kinds of amino acids in multi-amino-acid tablets by RP-HPLC method and amino acid analyzer

Dan Wan, Miao Chen, Yong Zhai

Open publisher page 0 citations

Abstract

Objective: To compare the methods of RP-HPLC and amino acid analyzer(AAA) for determining concentrations of amino acids.Methods: Eighteen kinds of amino acids in multi-amino-acid tablets were measured by an Agilent HPLC and Hitachi 835-50 amino acid analyzer.One C_(18) column was used for HPLC method with o-pathalaldehyde precolumn derivation.An ion exchange chromatography column was used for AAA method with ninhydrin postcolumn derivation.Results: The coefficients of variation of HPLC and AAA methods were less than 1.5% and 3.0%,respectively.The minimal detectable(limit) was 3 pmol for HPLC method and 30 pmol for AAA method.The results obtained from RP-HPLC were correlated to those of AAA method.The average relative standard deviation of the two methods was 5.74%(ranged from 0.24% to 9.60%).Conclusion: Both methods can be used to determine the concentrations of amino acids,but there is difference between the results of the two methods.

About this research paper

What this paper is about

Objective: To compare the methods of RP-HPLC and amino acid analyzer(AAA) for determining concentrations of amino acids.Methods: Eighteen kinds of amino acids in multi-amino-acid tablets were measured by an Agilent HPLC and Hitachi 835-50 amino acid analyzer.One C_(18) column was used for HPLC method with o-pathalaldehyde precolumn derivation.An ion exchange chromatography column was used for AAA method with ninhydrin postcolumn derivation.Results: The coefficients of variation of HPLC and AAA methods were less than 1.5% and 3.0%,respectively.The minimal detectable(limit) was 3 pmol for HPLC method and 30 pmol for AAA method.The results obtained from RP-HPLC were correlated to those of AAA method.The average relative standard deviation of the two methods was 5.74%(ranged from 0.24% to 9.60%).Conclusion: Both methods can be used to determine the concentrations of amino acids,but there is difference between the results of the two methods.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To compare the methods of RP-HPLC and amino acid analyzer(AAA) for determining concentrations of amino acids.Methods: Eighteen kinds of amino acids in multi-amino-acid tablets were measured by an Agilent HPLC and Hitachi 835-50 amino acid analyzer.One C_(18) column was used for HPLC method with o-pathalaldehyde precolumn derivation.An ion exchange chromatography column was used for AAA method with ninhydrin postcolumn derivation.Results: The coefficients of variation of HPLC and AAA methods were less than 1.5% and 3.0%,respectively.The minimal detectable(limit) was 3 pmol for HPLC method and 30 pmol for AAA method.The results obtained from RP-HPLC were correlated to those of AAA method.The average relative standard deviation of the two methods was 5.74%(ranged from 0.24% to 9.60%).Conclusion: Both methods can be used to determine the concentrations of amino acids,but there is difference between the results of the two methods.

Key concepts: High-performance liquid chromatography, Chromatography, Ninhydrin, Amino acid, Chemistry, Amino acid analysis, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of 18 kinds of amino acids in multi-amino-acid tablets by RP-HPLC method and amino acid analyzer — Research Paper | ScholarLens