Comparison of Free Amino Acids in Soybean Paste (Doenjang) by Different Extraction Solvents and Analytical Methods
Ok-Ju Kang
Abstract
Ok-Ju Kang
Abstract
This work was conducted to obtain a rapid, accurate, and precise procedure for free amino acids analysis in Doenjang with HPLC-OPA (high performance liquid chromatography using-phthalaldehyde) and AAA (automatic amino acid analyzer) methods. Different sample extraction procedures among water, 0.1 M perchloric acid, and 0.1% meta-phosphoric acid were also compared. The optimal extraction solvent was 0.1% meta-phosphoric acid for both the HPLC-OPA and AAA methods. Good recoveries for glycine and methionine were observed using the 0.1% meta-phosphoric acid extraction with HPLC-OPA method. Method precisions (% relative standard deviation) for the free amino acids ranged for 1.62% to 8.27%, in which the HPLC-OPA method with water extraction showed the lowest value at 1.62%. Inhibition rates of the free amino acids in Doenjang were greatest with an addition of NaCI at a 1% concentration.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
This work was conducted to obtain a rapid, accurate, and precise procedure for free amino acids analysis in Doenjang with HPLC-OPA (high performance liquid chromatography using-phthalaldehyde) and AAA (automatic amino acid analyzer) methods. Different sample extraction procedures among water, 0.1 M perchloric acid, and 0.1% meta-phosphoric acid were also compared. The optimal extraction solvent was 0.1% meta-phosphoric acid for both the HPLC-OPA and AAA methods. Good recoveries for glycine and methionine were observed using the 0.1% meta-phosphoric acid extraction with HPLC-OPA method. Method precisions (% relative standard deviation) for the free amino acids ranged for 1.62% to 8.27%, in which the HPLC-OPA method with water extraction showed the lowest value at 1.62%. Inhibition rates of the free amino acids in Doenjang were greatest with an addition of NaCI at a 1% concentration.
Key concepts: Phosphoric acid, Chromatography, High-performance liquid chromatography, Chemistry, Extraction (chemistry), Perchloric acid, Amino acid, Glycine