2002•Lishizhen Medicine and Materia Medica ResearchRequires access

Determination of Ferulic Acid in Duodongan Oral Solution by HPLC

Tan Xuan-zhong

Open publisher page 0 citations

Abstract

Objective:To use a PR-HPLC method for determination of ferulic acid in Liquid of Duodongan.Methods:The sample was prepared by macroporous resin DA 201. The determination was carried out on Spherisob C 18 ODS (5 μm,4.6 mm×300 mm) column with mobile phase of MeOH-1% acetic acid (4∶6).Results:Sample size showed a good linear relationship at the range of 0.01~0.09 μg and correlation coefficient was 0.999 7. The average recovery of added sample was 96.69% (n=5). RSD was 1.0%.Conclusion:The method is simple, accurate, reproducible.

About this research paper

What this paper is about

Objective:To use a PR-HPLC method for determination of ferulic acid in Liquid of Duodongan.Methods:The sample was prepared by macroporous resin DA 201. The determination was carried out on Spherisob C 18 ODS (5 μm,4.6 mm×300 mm) column with mobile phase of MeOH-1% acetic acid (4∶6).Results:Sample size showed a good linear relationship at the range of 0.01~0.09 μg and correlation coefficient was 0.999 7. The average recovery of added sample was 96.69% (n=5). RSD was 1.0%.Conclusion:The method is simple, accurate, reproducible.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To use a PR-HPLC method for determination of ferulic acid in Liquid of Duodongan.Methods:The sample was prepared by macroporous resin DA 201. The determination was carried out on Spherisob C 18 ODS (5 μm,4.6 mm×300 mm) column with mobile phase of MeOH-1% acetic acid (4∶6).Results:Sample size showed a good linear relationship at the range of 0.01~0.09 μg and correlation coefficient was 0.999 7. The average recovery of added sample was 96.69% (n=5). RSD was 1.0%.Conclusion:The method is simple, accurate, reproducible.

Key concepts: Ferulic acid, Chromatography, High-performance liquid chromatography, Chemistry, Acetic acid, Correlation coefficient, Linear correlation, Linear relationship

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Ferulic Acid in Duodongan Oral Solution by HPLC — Research Paper | ScholarLens