2013Chinese Journal of General PracticeRequires access

Comparison of Efficacy and Safety of Blood Specimen Collection via Radial Artery and Femoral Vein Puncture in Neonates

Chen Su-jua

Open publisher page 0 citations

Abstract

Objective To compare the efficacy and safety of blood specimen collection of neonates via radial artery and femoral vein puncture.Methods From March 2010 to February 2012,one hundred and eighty neonates were performed with blood specimen collection,and randomly divided into radial artery puncture group and femoral vein puncture group with 90 cases in each group.The success rate of one-time puncture,time of blood sampling,and incidence of adverse events associated with puncture(local damage) were compared between 2 groups.Results Comparing with femoral vein puncture group,a significantly higher success rate of one-time puncture(96.6% vs.85.6%,P 0.05) and shorter time of blood sampling[(4.10 ± 1.04) min vs.(6.4 ±1.21) min,P 0.01) ]were observed in radial artery puncture group.For radial artery puncture group,the local damage occurred in 7 cases,including 2 cases of hematoma,5 cases of bruising / petechiae.For femoral vein puncture group,local damage occurred in 34 cases,including 11 cases of hematoma,17 cases of bruising / petechiae,and 6 cases of red swelling.The incidence of adverse events associated with puncture in radial artery puncture blood group was significantly lower than that in femoral vein puncture group(7.8% vs.37.8%,P 0.01).Conclusion Neonatal radial artery puncture is a simple,effective and safe methods of blood sampling,which is worthy of clinical application.

About this research paper

What this paper is about

Objective To compare the efficacy and safety of blood specimen collection of neonates via radial artery and femoral vein puncture.Methods From March 2010 to February 2012,one hundred and eighty neonates were performed with blood specimen collection,and randomly divided into radial artery puncture group and femoral vein puncture group with 90 cases in each group.The success rate of one-time puncture,time of blood sampling,and incidence of adverse events associated with puncture(local damage) were compared between 2 groups.Results Comparing with femoral vein puncture group,a significantly higher success rate of one-time puncture(96.6% vs.85.6%,P 0.05) and shorter time of blood sampling[(4.10 ± 1.04) min vs.(6.4 ±1.21) min,P 0.01) ]were observed in radial artery puncture group.For radial artery puncture group,the local damage occurred in 7 cases,including 2 cases of hematoma,5 cases of bruising / petechiae.For femoral vein puncture group,local damage occurred in 34 cases,including 11 cases of hematoma,17 cases of bruising / petechiae,and 6 cases of red swelling.The incidence of adverse events associated with puncture in radial artery puncture blood group was significantly lower than that in femoral vein puncture group(7.8% vs.37.8%,P 0.01).Conclusion Neonatal radial artery puncture is a simple,effective and safe methods of blood sampling,which is worthy of clinical application.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare the efficacy and safety of blood specimen collection of neonates via radial artery and femoral vein puncture.Methods From March 2010 to February 2012,one hundred and eighty neonates were performed with blood specimen collection,and randomly divided into radial artery puncture group and femoral vein puncture group with 90 cases in each group.The success rate of one-time puncture,time of blood sampling,and incidence of adverse events associated with puncture(local damage) were compared between 2 groups.Results Comparing with femoral vein puncture group,a significantly higher success rate of one-time puncture(96.6% vs.85.6%,P 0.05) and shorter time of blood sampling[(4.10 ± 1.04) min vs.(6.4 ±1.21) min,P 0.01) ]were observed in radial artery puncture group.For radial artery puncture group,the local damage occurred in 7 cases,including 2 cases of hematoma,5 cases of bruising / petechiae.For femoral vein puncture group,local damage occurred in 34 cases,including 11 cases of hematoma,17 cases of bruising / petechiae,and 6 cases of red swelling.The incidence of adverse events associated with puncture in radial artery puncture blood group was significantly lower than that in femoral vein puncture group(7.8% vs.37.8%,P 0.01).Conclusion Neonatal radial artery puncture is a simple,effective and safe methods of blood sampling,which is worthy of clinical application.

Key concepts: Medicine, Hematoma, Femoral artery, Radial artery, Surgery, Femoral vein, Vein, Incidence (geometry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Efficacy and Safety of Blood Specimen Collection via Radial Artery and Femoral Vein Puncture in Neonates — Research Paper | ScholarLens