2005•Food ScienceRequires access

Determination of Trace Bismuth and Cadmuim in Tea by Hydride Generation Atomic Fluorescence Spectrometry

Wei Guo

Open publisher page 0 citations

Abstract

A method was reported for the determination of trace bismuth and cadmium in the tea by hydride generation atomicfluorescence spectrometry. The effects of acid medium and reducing agent on the determination of Bi and Cd and coexisting elementswere studied. In the given conditions, the detection limits were Bi:0.0946μg/L and Cd:0.0280μg/L respectively. The linear rangesof determination were Bi:0.1~200μg/L and Cd: 0.1~100μg/L respectively. The average recovery was in the range of 96.1%~108.6%. The method was accurate, rapid and convenient with satisfactory results.

About this research paper

What this paper is about

A method was reported for the determination of trace bismuth and cadmium in the tea by hydride generation atomicfluorescence spectrometry. The effects of acid medium and reducing agent on the determination of Bi and Cd and coexisting elementswere studied. In the given conditions, the detection limits were Bi:0.0946μg/L and Cd:0.0280μg/L respectively. The linear rangesof determination were Bi:0.1~200μg/L and Cd: 0.1~100μg/L respectively. The average recovery was in the range of 96.1%~108.6%. The method was accurate, rapid and convenient with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was reported for the determination of trace bismuth and cadmium in the tea by hydride generation atomicfluorescence spectrometry. The effects of acid medium and reducing agent on the determination of Bi and Cd and coexisting elementswere studied. In the given conditions, the detection limits were Bi:0.0946μg/L and Cd:0.0280μg/L respectively. The linear rangesof determination were Bi:0.1~200μg/L and Cd: 0.1~100μg/L respectively. The average recovery was in the range of 96.1%~108.6%. The method was accurate, rapid and convenient with satisfactory results.

Key concepts: Bismuth, Hydride, Chemistry, Cadmium, Linear range, Detection limit, Mass spectrometry, Trace Amounts

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Bismuth and Cadmuim in Tea by Hydride Generation Atomic Fluorescence Spectrometry — Research Paper | ScholarLens