2013Zhongguo tiedao kexueRequires access

Bending Stiffness of Segment Joint and Its Effects on Segment Internal Force for Underwater Shield Tunnel with Large Cross-Section

Guo Ru

Open publisher page 2 citations

Abstract

Taking Shiziyang tunnel which is an underwater railway shield tunnel with large cross-section as the research object,the bending stiffness of the circumferential segment joint was studied using the finite element numerical analysis method combined with prototype bending test of segment joint.Then beamspring model was applied to analyze the effects of joint bending stiffness on the internal force of the whole segment.Results show that the value range of joint bending stiffness is from 50to 700MN·m·rad-1.Under the same axial force,the joint bending stiffness will reduce an order of magnitude with the increase of joint bending moment.Under the same joint bending moment,the joint bending stiffness will increase with the increase of axial force.The joint bending stiffness has a weak influence on the axial force distribution of the segment,and has a significant influence on segment bending moment.The bending moment distribution of the whole segment tends to be uniform as the joint bending stiffness increases.In the range of bending stiffness,the maximum difference of the moment extremum reaches about 80%,the maximum reduction of the axial force extremum is about 5%,and the maximum reduction of the deformation is about20%.The improved beam-spring model considering the nonlinear relationship between joint bending stiffness and moment,axial force can better reflect the influence of the joint on the whole segment structure mechanics.It is more suitable for the calculation of the segment internal force for large cross-section shield tunnel.

About this research paper

What this paper is about

Taking Shiziyang tunnel which is an underwater railway shield tunnel with large cross-section as the research object,the bending stiffness of the circumferential segment joint was studied using the finite element numerical analysis method combined with prototype bending test of segment joint.Then beamspring model was applied to analyze the effects of joint bending stiffness on the internal force of the whole segment.Results show that the value range of joint bending stiffness is from 50to 700MN·m·rad-1.Under the same axial force,the joint bending stiffness will reduce an order of magnitude with the increase of joint bending moment.Under the same joint bending moment,the joint bending stiffness will increase with the increase of axial force.The joint bending stiffness has a weak influence on the axial force distribution of the segment,and has a significant influence on segment bending moment.The bending moment distribution of the whole segment tends to be uniform as the joint bending stiffness increases.In the range of bending stiffness,the maximum difference of the moment extremum reaches about 80%,the maximum reduction of the axial force extremum is about 5%,and the maximum reduction of the deformation is about20%.The improved beam-spring model considering the nonlinear relationship between joint bending stiffness and moment,axial force can better reflect the influence of the joint on the whole segment structure mechanics.It is more suitable for the calculation of the segment internal force for large cross-section shield tunnel.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Taking Shiziyang tunnel which is an underwater railway shield tunnel with large cross-section as the research object,the bending stiffness of the circumferential segment joint was studied using the finite element numerical analysis method combined with prototype bending test of segment joint.Then beamspring model was applied to analyze the effects of joint bending stiffness on the internal force of the whole segment.Results show that the value range of joint bending stiffness is from 50to 700MN·m·rad-1.Under the same axial force,the joint bending stiffness will reduce an order of magnitude with the increase of joint bending moment.Under the same joint bending moment,the joint bending stiffness will increase with the increase of axial force.The joint bending stiffness has a weak influence on the axial force distribution of the segment,and has a significant influence on segment bending moment.The bending moment distribution of the whole segment tends to be uniform as the joint bending stiffness increases.In the range of bending stiffness,the maximum difference of the moment extremum reaches about 80%,the maximum reduction of the axial force extremum is about 5%,and the maximum reduction of the deformation is about20%.The improved beam-spring model considering the nonlinear relationship between joint bending stiffness and moment,axial force can better reflect the influence of the joint on the whole segment structure mechanics.It is more suitable for the calculation of the segment internal force for large cross-section shield tunnel.

Key concepts: Bending stiffness, Bending moment, Stiffness, Structural engineering, Joint (building), Pure bending, Shear and moment diagram, Plastic bending

Related papers

Back to paper searchBrowse research topicsOriginal source
Bending Stiffness of Segment Joint and Its Effects on Segment Internal Force for Underwater Shield Tunnel with Large Cross-Section — Research Paper | ScholarLens