2011Clinical Medical EngineeringRequires access

Comparison of ELISA and ECLIA in Testing HBsAg Weak Reactive Samples

Shuqin Dai

Open publisher page 0 citations

Abstract

Objective To compare the results of enzyme linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA) in testing HBsAg weak reactive samples. Methods 824 HBsAg weak reactive serum samples, which had been tested by ELISA and their S/CO were 0.7 ~ 5.0, were re-tested by the ECLIA. Results ①352 serum samples' S/CO were 0.7 ~ 0.99, the qualitation was negative by ELISA, but COI≥1.0 in 48 samples by ECLIA (positive), there were significant differences (P 0.05); ②432 serum samples' S/CO were 1.0 ~ LPC (the QC of the weak positive), the qualitation was positive by ELISA, but COI1.0 in 248 samples by ECLIA (negative), there were statistically significant differences (P 0.01); ③40 serum samples' S/CO were LPC ~ 5.0, the qualitation was positive by ELISA, and COI≥1.0 in all 5 samples by ECLIA (positive). Conclusion In the cases of 0.7S/CO0.99, ECLIA is better than ELISA in the sensitiveness; when S/CO are 1.0 ~ LPC, ELISA is effected by many factors, so it easily leads to false positive results and we shall analyze the reasons and further review; when S/CO are LPC ~ 5.0, both methods can accurately determine.

About this research paper

What this paper is about

Objective To compare the results of enzyme linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA) in testing HBsAg weak reactive samples. Methods 824 HBsAg weak reactive serum samples, which had been tested by ELISA and their S/CO were 0.7 ~ 5.0, were re-tested by the ECLIA. Results ①352 serum samples' S/CO were 0.7 ~ 0.99, the qualitation was negative by ELISA, but COI≥1.0 in 48 samples by ECLIA (positive), there were significant differences (P 0.05); ②432 serum samples' S/CO were 1.0 ~ LPC (the QC of the weak positive), the qualitation was positive by ELISA, but COI1.0 in 248 samples by ECLIA (negative), there were statistically significant differences (P 0.01); ③40 serum samples' S/CO were LPC ~ 5.0, the qualitation was positive by ELISA, and COI≥1.0 in all 5 samples by ECLIA (positive). Conclusion In the cases of 0.7S/CO0.99, ECLIA is better than ELISA in the sensitiveness; when S/CO are 1.0 ~ LPC, ELISA is effected by many factors, so it easily leads to false positive results and we shall analyze the reasons and further review; when S/CO are LPC ~ 5.0, both methods can accurately determine.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare the results of enzyme linked immunosorbent assay (ELISA) and electrochemiluminescence immunoassay (ECLIA) in testing HBsAg weak reactive samples. Methods 824 HBsAg weak reactive serum samples, which had been tested by ELISA and their S/CO were 0.7 ~ 5.0, were re-tested by the ECLIA. Results ①352 serum samples' S/CO were 0.7 ~ 0.99, the qualitation was negative by ELISA, but COI≥1.0 in 48 samples by ECLIA (positive), there were significant differences (P 0.05); ②432 serum samples' S/CO were 1.0 ~ LPC (the QC of the weak positive), the qualitation was positive by ELISA, but COI1.0 in 248 samples by ECLIA (negative), there were statistically significant differences (P 0.01); ③40 serum samples' S/CO were LPC ~ 5.0, the qualitation was positive by ELISA, and COI≥1.0 in all 5 samples by ECLIA (positive). Conclusion In the cases of 0.7S/CO0.99, ECLIA is better than ELISA in the sensitiveness; when S/CO are 1.0 ~ LPC, ELISA is effected by many factors, so it easily leads to false positive results and we shall analyze the reasons and further review; when S/CO are LPC ~ 5.0, both methods can accurately determine.

Key concepts: Medicine, HBsAg, Internal medicine, Gastroenterology, Immunology, Virus, Hepatitis B virus

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of ELISA and ECLIA in Testing HBsAg Weak Reactive Samples — Research Paper | ScholarLens