Evaluation of electrochemiluminescene immunoassay and enzyme-linked immunosorbent assay for serum HBsAb detection
Caiyun Ma, Li Jiang, Ge Gaoxia, Xiaojie Zhang
Abstract
Caiyun Ma, Li Jiang, Ge Gaoxia, Xiaojie Zhang
Abstract
Electrochemiluminescene immunoassay(ECLIA) and enzyme-linked immunosorbent(ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA.The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values,4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively.The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L.Only in 3 samples, the results measured by ECLIA and ELISA were different(ECLIA: positive;ELISA:negative)among 165 samples.It is concluded that the method of ECLIA is more efficient than ELISA for detection of HBsAb in serum.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Electrochemiluminescene immunoassay(ECLIA) and enzyme-linked immunosorbent(ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA.The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values,4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively.The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L.Only in 3 samples, the results measured by ECLIA and ELISA were different(ECLIA: positive;ELISA:negative)among 165 samples.It is concluded that the method of ECLIA is more efficient than ELISA for detection of HBsAb in serum.
Key concepts: Medicine, Immunoassay, Coefficient of variation, Serum concentration, Internal medicine, Immunology, Chromatography, Antibody