Evaluation of electrochemiluminescene immunoassay and enzyme-linked immunosorbent assay for serum HBsAb detection

Caiyun Ma, Li Jiang, Ge Gaoxia, Xiaojie Zhang

Open publisher page 0 citations

Abstract

Electrochemiluminescene immunoassay(ECLIA) and enzyme-linked immunosorbent(ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA.The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values,4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively.The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L.Only in 3 samples, the results measured by ECLIA and ELISA were different(ECLIA: positive;ELISA:negative)among 165 samples.It is concluded that the method of ECLIA is more efficient than ELISA for detection of HBsAb in serum.

About this research paper

What this paper is about

Electrochemiluminescene immunoassay(ECLIA) and enzyme-linked immunosorbent(ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA.The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values,4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively.The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L.Only in 3 samples, the results measured by ECLIA and ELISA were different(ECLIA: positive;ELISA:negative)among 165 samples.It is concluded that the method of ECLIA is more efficient than ELISA for detection of HBsAb in serum.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Electrochemiluminescene immunoassay(ECLIA) and enzyme-linked immunosorbent(ELISA) were used to detect the different concentrations of serum HBsAb, in order to compare the results of ECLIA and ELISA.The result showed that intra-assay coefficient of variation of ECLIA was about 0.95% for high value, 1.13% for mean values and 2.63% for low value, while that of ELISA was about 5.76%, 12.8% and 15.9%, respectively. The interassay coefficient of ECLIA was about 4.03% for high values,4.93% for mean values and 7.34% for low values, while that of ELISA was about 10.1%, 19.6% and 25.2%, respectively.The analytical sensitivity of ECLIA was about 4.0IU/L, while that of ELISA is about 19.0IU/L.Only in 3 samples, the results measured by ECLIA and ELISA were different(ECLIA: positive;ELISA:negative)among 165 samples.It is concluded that the method of ECLIA is more efficient than ELISA for detection of HBsAb in serum.

Key concepts: Medicine, Immunoassay, Coefficient of variation, Serum concentration, Internal medicine, Immunology, Chromatography, Antibody

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of electrochemiluminescene immunoassay and enzyme-linked immunosorbent assay for serum HBsAb detection — Research Paper | ScholarLens