2011Nanjing Zhongyiyao Daxue xuebaoRequires access

Determination of Solvent Residues in Polysorbate-80 by Headspace Gas Chromatography

Jun Li

Open publisher page 0 citations

Abstract

OBJECTIVE To determine the solvent residues in polysorbate-80 by establishing headspace gas chromatography(HS-GC).METHODS HS-GC with capillary column Agilent DB-624 as chromatographic column and n-butanol as the internal standard was adopted.RESULTS The linear ranges of chloroform,dichloromethane,ethylene glycol and diethylene glycol were 6.73~1 346 μg/mL,6.34~1 268 μg/mL,3.30~660 μg/mL and 1.87~374 μg/mL respectively.The detection limits of the four residual solvents were 2.02,1.90,0.009 9 and 0.005 7 μg/mL respectively.CONCLUSION This method is proved to be sensitive,accurate and specific.It can effectively determine the four solvent residues in polysorbate-80.

About this research paper

What this paper is about

OBJECTIVE To determine the solvent residues in polysorbate-80 by establishing headspace gas chromatography(HS-GC).METHODS HS-GC with capillary column Agilent DB-624 as chromatographic column and n-butanol as the internal standard was adopted.RESULTS The linear ranges of chloroform,dichloromethane,ethylene glycol and diethylene glycol were 6.73~1 346 μg/mL,6.34~1 268 μg/mL,3.30~660 μg/mL and 1.87~374 μg/mL respectively.The detection limits of the four residual solvents were 2.02,1.90,0.009 9 and 0.005 7 μg/mL respectively.CONCLUSION This method is proved to be sensitive,accurate and specific.It can effectively determine the four solvent residues in polysorbate-80.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To determine the solvent residues in polysorbate-80 by establishing headspace gas chromatography(HS-GC).METHODS HS-GC with capillary column Agilent DB-624 as chromatographic column and n-butanol as the internal standard was adopted.RESULTS The linear ranges of chloroform,dichloromethane,ethylene glycol and diethylene glycol were 6.73~1 346 μg/mL,6.34~1 268 μg/mL,3.30~660 μg/mL and 1.87~374 μg/mL respectively.The detection limits of the four residual solvents were 2.02,1.90,0.009 9 and 0.005 7 μg/mL respectively.CONCLUSION This method is proved to be sensitive,accurate and specific.It can effectively determine the four solvent residues in polysorbate-80.

Key concepts: Chromatography, Chemistry, Solvent, Dichloromethane, Ethylene glycol, Gas chromatography, Chloroform, Diethylene glycol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Solvent Residues in Polysorbate-80 by Headspace Gas Chromatography — Research Paper | ScholarLens