2008Huaxi yaoxue zazhiRequires access

Determination of organic solvent residue in Folic acid tablets by headspace GC

Lili Chen

Open publisher page 0 citations

Abstract

OBJECTIVE To determine organic solvent residue in Folic acid tablets by headspace gas chromatography.METHODSRtx-1(30 m×025 mm,0.25μm) capillary column was used with column temperature was controlled temperature programming,and be set at 200℃.RESULTSThe linear ranges of methanol,acetone,chloroform and methylbenzene were 1.129-24.030 μg·ml-1(r=0.9992),0.566-0.999 μg·ml-1(r=0.9995),1.067-21.030 μg·ml-1(r=0.9995)and 1.264-24.920 μg·ml-1(r=0.9993).The average recovery was 99.2%,100.4%,101.3% and 99.8% with RSD of 1.92%,2.02%,1.64% and 2.01%.CONCLUSIONThe method is simple,accurate,sensitive and reproducible.

About this research paper

What this paper is about

OBJECTIVE To determine organic solvent residue in Folic acid tablets by headspace gas chromatography.METHODSRtx-1(30 m×025 mm,0.25μm) capillary column was used with column temperature was controlled temperature programming,and be set at 200℃.RESULTSThe linear ranges of methanol,acetone,chloroform and methylbenzene were 1.129-24.030 μg·ml-1(r=0.9992),0.566-0.999 μg·ml-1(r=0.9995),1.067-21.030 μg·ml-1(r=0.9995)and 1.264-24.920 μg·ml-1(r=0.9993).The average recovery was 99.2%,100.4%,101.3% and 99.8% with RSD of 1.92%,2.02%,1.64% and 2.01%.CONCLUSIONThe method is simple,accurate,sensitive and reproducible.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To determine organic solvent residue in Folic acid tablets by headspace gas chromatography.METHODSRtx-1(30 m×025 mm,0.25μm) capillary column was used with column temperature was controlled temperature programming,and be set at 200℃.RESULTSThe linear ranges of methanol,acetone,chloroform and methylbenzene were 1.129-24.030 μg·ml-1(r=0.9992),0.566-0.999 μg·ml-1(r=0.9995),1.067-21.030 μg·ml-1(r=0.9995)and 1.264-24.920 μg·ml-1(r=0.9993).The average recovery was 99.2%,100.4%,101.3% and 99.8% with RSD of 1.92%,2.02%,1.64% and 2.01%.CONCLUSIONThe method is simple,accurate,sensitive and reproducible.

Key concepts: Chemistry, Chromatography, Chloroform, Acetone, Residue (chemistry), Solvent, Methanol, Gas chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of organic solvent residue in Folic acid tablets by headspace GC — Research Paper | ScholarLens