2010China Medical HeraldRequires access

Content determination of ginsenoside Rg_1,ginsenoside Rb_1 and notoginsenoside R_1 in Shuxiong Tablets by RP-HPLC

WU Yizhong

Open publisher page 0 citations

Abstract

Objective:To establish a method for the content determination of ginsenoside Rg1,ginsenoside Rb1 and noto ginsenoside R1 in Shuxiong Tablets by RP-HPLC. Methods:The Shim-pack-C18 (4.6 mm×250 mm,5 μm) column was used. The mobile phases consisted of acetonitrile and water (gradient elution),the flow rate was 1.0 ml/min and the detection wavelength was at 203 nm. Results:The linear ranges of ginsenoside Rg1 was at 0.82-8.20 μg; the linear ranges of ginsenoside Rb1 was at 0.88-8.80 μg; the linear ranges of notoginsenoside R1 was at 0.32-3.20 μg. The average recovery was 99.76% with a RSD of 1.26%. Conclusion:The method is fast,reliable,accurate and can be used in the quality con-trol of ginsenoside Rg1,ginsenoside Rb1 and notoginsenoside in Shuxiong Tablets.

About this research paper

What this paper is about

Objective:To establish a method for the content determination of ginsenoside Rg1,ginsenoside Rb1 and noto ginsenoside R1 in Shuxiong Tablets by RP-HPLC. Methods:The Shim-pack-C18 (4.6 mm×250 mm,5 μm) column was used. The mobile phases consisted of acetonitrile and water (gradient elution),the flow rate was 1.0 ml/min and the detection wavelength was at 203 nm. Results:The linear ranges of ginsenoside Rg1 was at 0.82-8.20 μg; the linear ranges of ginsenoside Rb1 was at 0.88-8.80 μg; the linear ranges of notoginsenoside R1 was at 0.32-3.20 μg. The average recovery was 99.76% with a RSD of 1.26%. Conclusion:The method is fast,reliable,accurate and can be used in the quality con-trol of ginsenoside Rg1,ginsenoside Rb1 and notoginsenoside in Shuxiong Tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a method for the content determination of ginsenoside Rg1,ginsenoside Rb1 and noto ginsenoside R1 in Shuxiong Tablets by RP-HPLC. Methods:The Shim-pack-C18 (4.6 mm×250 mm,5 μm) column was used. The mobile phases consisted of acetonitrile and water (gradient elution),the flow rate was 1.0 ml/min and the detection wavelength was at 203 nm. Results:The linear ranges of ginsenoside Rg1 was at 0.82-8.20 μg; the linear ranges of ginsenoside Rb1 was at 0.88-8.80 μg; the linear ranges of notoginsenoside R1 was at 0.32-3.20 μg. The average recovery was 99.76% with a RSD of 1.26%. Conclusion:The method is fast,reliable,accurate and can be used in the quality con-trol of ginsenoside Rg1,ginsenoside Rb1 and notoginsenoside in Shuxiong Tablets.

Key concepts: Ginsenoside Rg1, Ginsenoside, Chromatography, Medicine, Gradient elution, High-performance liquid chromatography, Linear relationship, Content determination

Related papers

Back to paper searchBrowse research topicsOriginal source
Content determination of ginsenoside Rg_1,ginsenoside Rb_1 and notoginsenoside R_1 in Shuxiong Tablets by RP-HPLC — Research Paper | ScholarLens