The observation of optical method of platelet count by XE-2100 hematology analyzer in clinical application
Baode Chen
Abstract
Baode Chen
Abstract
Objective:To understand the accuracy of the optical platelet count with XE-2100 hematology analyzer prompted to open RET-CH and the platelet count the results of suspicious samples to guide applications in different disease.Methods: Collect apparatus prompted to open RET-CH and the platelet count of suspicious specimens 225 cases,the impedance method (PLT-I),the optical method(PLT-O),microscopic(PLT-M) platelet count,and at the same time push the system stained blood film examination,observation of small red blood cells,red blood cell debris,large platelets,platelet aggregation,will be a small red blood cells and / or red blood cell debris,large platelets,platelet aggregation in samples divided into 3 groups according to clinical diagnosis of the remaining samples are divided into 5 group.Results: Microscopic examination found a small red blood cells and / or red blood cell fragments in 38 cases,15 cases of large platelets,platelet aggregation 5 cases,In a small red blood cells and / or red blood cell debris group,liver cirrhosis group,leukemia group,lymphoma group,Large platelet groups,Post-operative Group,platelet count optical method and reference method-microscopic correlation better,cancer Disease group PLT-I and PLT-O with the PLT-M is similar to the correlation. Conclusion: XE-2100 optical method of platelet count in a small red blood cell group,hepatitis,liver cirrhosis group,leukemia group,lymphoma group,Large platelet groups,Post-operative Group of the advantages of good,in the cancer group,no difference;so,when the apparatus prompted to open RET-CH and the platelet count suspicious should be carried out platelet count with optical method to ensure accurate results.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To understand the accuracy of the optical platelet count with XE-2100 hematology analyzer prompted to open RET-CH and the platelet count the results of suspicious samples to guide applications in different disease.Methods: Collect apparatus prompted to open RET-CH and the platelet count of suspicious specimens 225 cases,the impedance method (PLT-I),the optical method(PLT-O),microscopic(PLT-M) platelet count,and at the same time push the system stained blood film examination,observation of small red blood cells,red blood cell debris,large platelets,platelet aggregation,will be a small red blood cells and / or red blood cell debris,large platelets,platelet aggregation in samples divided into 3 groups according to clinical diagnosis of the remaining samples are divided into 5 group.Results: Microscopic examination found a small red blood cells and / or red blood cell fragments in 38 cases,15 cases of large platelets,platelet aggregation 5 cases,In a small red blood cells and / or red blood cell debris group,liver cirrhosis group,leukemia group,lymphoma group,Large platelet groups,Post-operative Group,platelet count optical method and reference method-microscopic correlation better,cancer Disease group PLT-I and PLT-O with the PLT-M is similar to the correlation. Conclusion: XE-2100 optical method of platelet count in a small red blood cell group,hepatitis,liver cirrhosis group,leukemia group,lymphoma group,Large platelet groups,Post-operative Group of the advantages of good,in the cancer group,no difference;so,when the apparatus prompted to open RET-CH and the platelet count suspicious should be carried out platelet count with optical method to ensure accurate results.
Key concepts: Platelet, Medicine, Blood cell, Hematology, Hematology analyzer, Gastroenterology, Cirrhosis, Internal medicine