2011•Journal of Hubei University of Chinese MedicineRequires access

Determination of Chlorogenic Acid in Yinqiao Jiedu Granules by RP-HPLC

Xiang Meixian

Open publisher page 0 citations

Abstract

Objective To establish the method for determining Chlorogenic acid in Yinqiao Jiedu granules by RP-HPLC.Methods The HPLC conditions with DIONEX-ACCLAIM.120 C18 column(250mm×4.6mm,5μm)was used,the mobile phase was composed of methy1 cyanide and and PBS(pH=2.5) with gradient elution;flow rate was 1.0mL/min;column temperature was 35℃;the detective wavelength was 350nm.Results The linear ranges of Chlorogenic acid was 0.024μg-0.384μg/mL;r=0.9999.The average recoveries(n=6) of Chlorogenic acid was 93.56%;RSD was 1.15%.Conclusion The method is accurate,reproducible and highly selective,thus suitable for quality control of Yinqiao Jiedu granules.

About this research paper

What this paper is about

Objective To establish the method for determining Chlorogenic acid in Yinqiao Jiedu granules by RP-HPLC.Methods The HPLC conditions with DIONEX-ACCLAIM.120 C18 column(250mm×4.6mm,5μm)was used,the mobile phase was composed of methy1 cyanide and and PBS(pH=2.5) with gradient elution;flow rate was 1.0mL/min;column temperature was 35℃;the detective wavelength was 350nm.Results The linear ranges of Chlorogenic acid was 0.024μg-0.384μg/mL;r=0.9999.The average recoveries(n=6) of Chlorogenic acid was 93.56%;RSD was 1.15%.Conclusion The method is accurate,reproducible and highly selective,thus suitable for quality control of Yinqiao Jiedu granules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish the method for determining Chlorogenic acid in Yinqiao Jiedu granules by RP-HPLC.Methods The HPLC conditions with DIONEX-ACCLAIM.120 C18 column(250mm×4.6mm,5μm)was used,the mobile phase was composed of methy1 cyanide and and PBS(pH=2.5) with gradient elution;flow rate was 1.0mL/min;column temperature was 35℃;the detective wavelength was 350nm.Results The linear ranges of Chlorogenic acid was 0.024μg-0.384μg/mL;r=0.9999.The average recoveries(n=6) of Chlorogenic acid was 93.56%;RSD was 1.15%.Conclusion The method is accurate,reproducible and highly selective,thus suitable for quality control of Yinqiao Jiedu granules.

Key concepts: Chlorogenic acid, Chromatography, Chemistry, High-performance liquid chromatography, Gradient elution, Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorogenic Acid in Yinqiao Jiedu Granules by RP-HPLC — Research Paper | ScholarLens