2009Shenyang Yaoke Daxue xuebaoRequires access

Simultaneous determination of contents of berberine hydrochloride and quercetin in Migan granules by HPLC

Zhao Huai-qing

Open publisher page 0 citations

Abstract

Objective To establish an HPLC method for simultaneous determination of berberine hydrochloride and quercetin in Migan(traditional Chinese medicines) granules.Methods The chromatographic method was carried out on a Diamonsil C18 column(200 mm × 4.6 mm,5 μm)with acetonitrile-3% phosphoric acid solution(V∶V=34∶120,adjust pH value to 3 by triethylamine)as the mobile phase.The flow rate was 1.0 mL· min-1 and the column temperature was 30 ℃.The detection wavelength was set at 360 nm.Results The calibration curve was linear within the range of 1.040-10.40 mg·L-1(r=0.999 9)for berberine hydrochloride and 0.400-4.00 mg·L-1(r=0.999 8)for quercetin,the average recoveries were 98.5%(RSD=0.92%)for berberine hydrochloride and 98.8%(RSD=1.43%)for quercetin.Conclusions The method is simple,accurate and reproducible,which can be used for the quality control of Migan granules.

About this research paper

What this paper is about

Objective To establish an HPLC method for simultaneous determination of berberine hydrochloride and quercetin in Migan(traditional Chinese medicines) granules.Methods The chromatographic method was carried out on a Diamonsil C18 column(200 mm × 4.6 mm,5 μm)with acetonitrile-3% phosphoric acid solution(V∶V=34∶120,adjust pH value to 3 by triethylamine)as the mobile phase.The flow rate was 1.0 mL· min-1 and the column temperature was 30 ℃.The detection wavelength was set at 360 nm.Results The calibration curve was linear within the range of 1.040-10.40 mg·L-1(r=0.999 9)for berberine hydrochloride and 0.400-4.00 mg·L-1(r=0.999 8)for quercetin,the average recoveries were 98.5%(RSD=0.92%)for berberine hydrochloride and 98.8%(RSD=1.43%)for quercetin.Conclusions The method is simple,accurate and reproducible,which can be used for the quality control of Migan granules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish an HPLC method for simultaneous determination of berberine hydrochloride and quercetin in Migan(traditional Chinese medicines) granules.Methods The chromatographic method was carried out on a Diamonsil C18 column(200 mm × 4.6 mm,5 μm)with acetonitrile-3% phosphoric acid solution(V∶V=34∶120,adjust pH value to 3 by triethylamine)as the mobile phase.The flow rate was 1.0 mL· min-1 and the column temperature was 30 ℃.The detection wavelength was set at 360 nm.Results The calibration curve was linear within the range of 1.040-10.40 mg·L-1(r=0.999 9)for berberine hydrochloride and 0.400-4.00 mg·L-1(r=0.999 8)for quercetin,the average recoveries were 98.5%(RSD=0.92%)for berberine hydrochloride and 98.8%(RSD=1.43%)for quercetin.Conclusions The method is simple,accurate and reproducible,which can be used for the quality control of Migan granules.

Key concepts: Berberine hydrochloride, Chromatography, Chemistry, Phosphoric acid, High-performance liquid chromatography, Calibration curve, Triethylamine, Quercetin

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of contents of berberine hydrochloride and quercetin in Migan granules by HPLC — Research Paper | ScholarLens