2006Rock and Mineral AnalysisRequires access

Determination of Trace Cadmium in Foodstuff Samples by Hydride Generation Atomic Fluorescence Spectrometry with New Chemical Vapor Generation System

Yuhua Liu

Open publisher page 1 citations

Abstract

Based on the remarkable sensitivity enhancement effect of Co~(2+) on Cd,a new chemical vapor generation system of Cd-KBH_(4)-NaIO_(3)-HCl was developed for the determination of trace Cd in foodstuff samples by atomic fluorescence spectrometry(AFS).Under the optimized chemical and instrument conditions,the dosage of Co~(2+),as a signal enhancement reagent,was optimized.The interference from Cu,Ni,Zn,Mn,Au,Pt,Pd,Sb,Hg and Fe on the determination of Cd in this system and their elimination were also studied.The detection limit of the method is 0.035 μg/L for Cd.The method has been applied to the determination of trace Cd in national standard foodstuff samples and the results are in agreement with certified values with precision of 4.84% RSD(n=12).

About this research paper

What this paper is about

Based on the remarkable sensitivity enhancement effect of Co~(2+) on Cd,a new chemical vapor generation system of Cd-KBH_(4)-NaIO_(3)-HCl was developed for the determination of trace Cd in foodstuff samples by atomic fluorescence spectrometry(AFS).Under the optimized chemical and instrument conditions,the dosage of Co~(2+),as a signal enhancement reagent,was optimized.The interference from Cu,Ni,Zn,Mn,Au,Pt,Pd,Sb,Hg and Fe on the determination of Cd in this system and their elimination were also studied.The detection limit of the method is 0.035 μg/L for Cd.The method has been applied to the determination of trace Cd in national standard foodstuff samples and the results are in agreement with certified values with precision of 4.84% RSD(n=12).

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on the remarkable sensitivity enhancement effect of Co~(2+) on Cd,a new chemical vapor generation system of Cd-KBH_(4)-NaIO_(3)-HCl was developed for the determination of trace Cd in foodstuff samples by atomic fluorescence spectrometry(AFS).Under the optimized chemical and instrument conditions,the dosage of Co~(2+),as a signal enhancement reagent,was optimized.The interference from Cu,Ni,Zn,Mn,Au,Pt,Pd,Sb,Hg and Fe on the determination of Cd in this system and their elimination were also studied.The detection limit of the method is 0.035 μg/L for Cd.The method has been applied to the determination of trace Cd in national standard foodstuff samples and the results are in agreement with certified values with precision of 4.84% RSD(n=12).

Key concepts: Chemistry, Detection limit, Reagent, Hydride, Analytical Chemistry (journal), Cadmium, Mass spectrometry, Certified reference materials

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Cadmium in Foodstuff Samples by Hydride Generation Atomic Fluorescence Spectrometry with New Chemical Vapor Generation System — Research Paper | ScholarLens