2011•Dalian Gongye Daxue xuebaoRequires access

Determination of sunscreen agent UV-360 in cosmetic by reversed-phase high performance liquid chromatography

Lin Wei-xuan

Open publisher page 0 citations

Abstract

A reversed - phase high performance liquid chromatography was developed for determination of sunscreen agent UV-360 in cosmetics.A C18(250 mm×4.6 mm,5 μm) column was used and methanol - water was used as mobile phase.The wavelength 360 nm was selected for detection.Used V(carbon tetrachloride)∶V(methanol)=3∶7 as solvent extraction and the sample pre-treatment methods include ultrasonic extraction,centrifugal purification.The sample filtered by 0.45 μm membrane,directly into the analysis.The recovery lies 98.20%-102.40% and the relative standard deviation lies less than 5%.Detection limit is 0.005 μg.This method had the advantages of good separating effect and rapid analysis.

About this research paper

What this paper is about

A reversed - phase high performance liquid chromatography was developed for determination of sunscreen agent UV-360 in cosmetics.A C18(250 mm×4.6 mm,5 μm) column was used and methanol - water was used as mobile phase.The wavelength 360 nm was selected for detection.Used V(carbon tetrachloride)∶V(methanol)=3∶7 as solvent extraction and the sample pre-treatment methods include ultrasonic extraction,centrifugal purification.The sample filtered by 0.45 μm membrane,directly into the analysis.The recovery lies 98.20%-102.40% and the relative standard deviation lies less than 5%.Detection limit is 0.005 μg.This method had the advantages of good separating effect and rapid analysis.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A reversed - phase high performance liquid chromatography was developed for determination of sunscreen agent UV-360 in cosmetics.A C18(250 mm×4.6 mm,5 μm) column was used and methanol - water was used as mobile phase.The wavelength 360 nm was selected for detection.Used V(carbon tetrachloride)∶V(methanol)=3∶7 as solvent extraction and the sample pre-treatment methods include ultrasonic extraction,centrifugal purification.The sample filtered by 0.45 μm membrane,directly into the analysis.The recovery lies 98.20%-102.40% and the relative standard deviation lies less than 5%.Detection limit is 0.005 μg.This method had the advantages of good separating effect and rapid analysis.

Key concepts: Chromatography, Detection limit, Methanol, Extraction (chemistry), Solvent, Chemistry, High-performance liquid chromatography, Phase (matter)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of sunscreen agent UV-360 in cosmetic by reversed-phase high performance liquid chromatography — Research Paper | ScholarLens