2013Journal of Inner Mongolia Medical UniversityRequires access

SIMULTANEOUS DETERMINATION OF QUERCETIN AND KAEMPFEROL IN ERITRICHII HERBA BY HPLC

Lijuan Ma

Open publisher page 0 citations

Abstract

Objective:To establish a determination method of quercetin and kaempferol in Eritrichii Herba.Methods:HPLC was applied.The column was Eighteen alkyl silane bonded silica gel,the mobile phase was methanol~0.4%phosphoric acid(45∶ 50),the flow rate was 1.0 mL/ min and the detection wavelength was 368nm.Result:The linear range of Quercetin was 31.4~314 ng(r=0.9997),the average recovery was 96.96%(RSD=1.54%).The linear range of kaempferol was 30~300 ng(r=0.9999),the average recovery was 97.92%(RSD=1.91%).Conclusion:The method is simple,accurate,reproducible and can be used for the determination of quercetin and kaempferol in Eritrichii Herba.

About this research paper

What this paper is about

Objective:To establish a determination method of quercetin and kaempferol in Eritrichii Herba.Methods:HPLC was applied.The column was Eighteen alkyl silane bonded silica gel,the mobile phase was methanol~0.4%phosphoric acid(45∶ 50),the flow rate was 1.0 mL/ min and the detection wavelength was 368nm.Result:The linear range of Quercetin was 31.4~314 ng(r=0.9997),the average recovery was 96.96%(RSD=1.54%).The linear range of kaempferol was 30~300 ng(r=0.9999),the average recovery was 97.92%(RSD=1.91%).Conclusion:The method is simple,accurate,reproducible and can be used for the determination of quercetin and kaempferol in Eritrichii Herba.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a determination method of quercetin and kaempferol in Eritrichii Herba.Methods:HPLC was applied.The column was Eighteen alkyl silane bonded silica gel,the mobile phase was methanol~0.4%phosphoric acid(45∶ 50),the flow rate was 1.0 mL/ min and the detection wavelength was 368nm.Result:The linear range of Quercetin was 31.4~314 ng(r=0.9997),the average recovery was 96.96%(RSD=1.54%).The linear range of kaempferol was 30~300 ng(r=0.9999),the average recovery was 97.92%(RSD=1.91%).Conclusion:The method is simple,accurate,reproducible and can be used for the determination of quercetin and kaempferol in Eritrichii Herba.

Key concepts: Kaempferol, Quercetin, Phosphoric acid, Chromatography, Chemistry, High-performance liquid chromatography, Linear range, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
SIMULTANEOUS DETERMINATION OF QUERCETIN AND KAEMPFEROL IN ERITRICHII HERBA BY HPLC — Research Paper | ScholarLens