2008Physical Testing and Chemical AnalysisRequires access

HPLC Simultaneous Determination of Chlorogenic Acid and Baicalin in Shuanghuanglian Preparations

Yang Han-rong

Open publisher page 0 citations

Abstract

HPLC was applied to the simultaneous determination of chlorogenic acid and baicalin inShuanghuangliancompound preparations.Waters Symmetry C_(18) column(3.9 mm×150 mm,5μm)was used in the chromatographic separation,and a solution containing methanol and dilute,phosphoric acid was used as the mobile phase in the gradient elution,with a flow-rate of 0.8 mL·min~(-1).UV-detection at 320 nm was selected in the determination.Linearity range for determination of chlorogenic acid was found in the range of 1.72-137.6 mg·L~(-1)(y=28 900.12+23 036.71 x,r=0.999 6),and for determination of baicalin in the range of 3.35-267.9 mg·L~(-1)(y=19 940.40+13 564.15 x,r=0.999 8).The RSD's found in the precision test were 3.53%(n=7)for chlorogenic acid,and 2.85%(n=7)for baicalin,and average recovery obtained were 95.8% and 97.3% respectively.

About this research paper

What this paper is about

HPLC was applied to the simultaneous determination of chlorogenic acid and baicalin inShuanghuangliancompound preparations.Waters Symmetry C_(18) column(3.9 mm×150 mm,5μm)was used in the chromatographic separation,and a solution containing methanol and dilute,phosphoric acid was used as the mobile phase in the gradient elution,with a flow-rate of 0.8 mL·min~(-1).UV-detection at 320 nm was selected in the determination.Linearity range for determination of chlorogenic acid was found in the range of 1.72-137.6 mg·L~(-1)(y=28 900.12+23 036.71 x,r=0.999 6),and for determination of baicalin in the range of 3.35-267.9 mg·L~(-1)(y=19 940.40+13 564.15 x,r=0.999 8).The RSD's found in the precision test were 3.53%(n=7)for chlorogenic acid,and 2.85%(n=7)for baicalin,and average recovery obtained were 95.8% and 97.3% respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

HPLC was applied to the simultaneous determination of chlorogenic acid and baicalin inShuanghuangliancompound preparations.Waters Symmetry C_(18) column(3.9 mm×150 mm,5μm)was used in the chromatographic separation,and a solution containing methanol and dilute,phosphoric acid was used as the mobile phase in the gradient elution,with a flow-rate of 0.8 mL·min~(-1).UV-detection at 320 nm was selected in the determination.Linearity range for determination of chlorogenic acid was found in the range of 1.72-137.6 mg·L~(-1)(y=28 900.12+23 036.71 x,r=0.999 6),and for determination of baicalin in the range of 3.35-267.9 mg·L~(-1)(y=19 940.40+13 564.15 x,r=0.999 8).The RSD's found in the precision test were 3.53%(n=7)for chlorogenic acid,and 2.85%(n=7)for baicalin,and average recovery obtained were 95.8% and 97.3% respectively.

Key concepts: Baicalin, Chlorogenic acid, Chromatography, Chemistry, Phosphoric acid, High-performance liquid chromatography, Gradient elution, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC Simultaneous Determination of Chlorogenic Acid and Baicalin in Shuanghuanglian Preparations — Research Paper | ScholarLens