2011•China Medical HeraldRequires access

Content determination of Paeoniflorin in Huoxue Tongmai Tablets by HPLC

Xiong Xin

Open publisher page 0 citations

Abstract

Objective: To establish a method for the content determination of Paeoniflorin in Huoxue Tongmai Tablets by HPLC.Methods: The radix Paeoniae rubra was quantitative analysed by HPLC.The C18(4.6 mm×250 mm,5 μm) column was used.The mobile phases consisted of methanol and water(27∶73),the flow rate was 0.8 ml/min and the detection wavelength was at 230 nm.The temperature was 30℃.Results: The optimum linear relation of Peoniflorin was 0.98-7.35 μg,the average recovery rate was 97.52% with a RSD of 1.57%.Conclusion: The method is a accurate,recurring and easy to use assay for quality control.

About this research paper

What this paper is about

Objective: To establish a method for the content determination of Paeoniflorin in Huoxue Tongmai Tablets by HPLC.Methods: The radix Paeoniae rubra was quantitative analysed by HPLC.The C18(4.6 mm×250 mm,5 μm) column was used.The mobile phases consisted of methanol and water(27∶73),the flow rate was 0.8 ml/min and the detection wavelength was at 230 nm.The temperature was 30℃.Results: The optimum linear relation of Peoniflorin was 0.98-7.35 μg,the average recovery rate was 97.52% with a RSD of 1.57%.Conclusion: The method is a accurate,recurring and easy to use assay for quality control.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish a method for the content determination of Paeoniflorin in Huoxue Tongmai Tablets by HPLC.Methods: The radix Paeoniae rubra was quantitative analysed by HPLC.The C18(4.6 mm×250 mm,5 μm) column was used.The mobile phases consisted of methanol and water(27∶73),the flow rate was 0.8 ml/min and the detection wavelength was at 230 nm.The temperature was 30℃.Results: The optimum linear relation of Peoniflorin was 0.98-7.35 μg,the average recovery rate was 97.52% with a RSD of 1.57%.Conclusion: The method is a accurate,recurring and easy to use assay for quality control.

Key concepts: Paeoniflorin, Medicine, Chromatography, High-performance liquid chromatography, Content determination, Radix (gastropod), Linear relationship, Traditional medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Content determination of Paeoniflorin in Huoxue Tongmai Tablets by HPLC — Research Paper | ScholarLens